– 47 –
Error Codes
Error
Code
Description
Trigger Condition
Action
E00
No Error
There are no errors to display.
tE2
Inlet
Thermistor
Error
Thermistor voltage is over 4.8 V
for more than 5 seconds.
• Check Inlet Thermistor connector and
wiring.
• Replace the Thermistor 1 as necessary.
• Replace the PCB as necessary.
Thermistor voltage is under 0.2 V
for more than 5 seconds.
tE4
Outlet
Thermistor
Error
Thermistor voltage is over 4.8 V
for more than 5 seconds.
• Check Outlet Thermistor connector and
wiring.
• Replace the Thermistor 2 as necessary.
• Replace the PCB as necessary.
Thermistor voltage is under 0.2 V
for more than 5 seconds.
dE
Door Fail
Door interrupt voltage is
continuously low level for more
than 256 milliseconds.
• Check Door switch and Door switch
wiring.
• Replace the Door switch as necessary.
• Replace the PCB as necessary.
od
Over Dry
The dry and cooling process is
over 240 minutes.
(Failure mode equals stuck
heater relay. Replace MC board.)
• Check Thermistor 1 & 2 connector and
wiring.
• Replace the thermistor as necessary.
• Replace the PCB as necessary.
HE
Heating Error Heating Temperature is over
185 Fahrenheit for more than
10 seconds.
(Failure mode equals stuck
heater relay. Replace MC
board.)
• Check the Heater and Heater connector.
• Replace the PCB as necessary.
HE4
Heating Error
(Filter Check)
Clean lint
fi
lter condition
detected 3 consecutive times.
• Check the case
fi
lter & condenser
• Check the duct fan.
• Replace the PCB as necessary.
bE2
Button Error
When any key is continuously
pressed for more than 30
seconds.
• Check for stuck keys on panel.
• Replace the control panel as necessary.
• Replace the PCB as necessary.
3E1
Motor Relay
Open
When the motor state is
"running", the control detects
the high motor signal within
120 seconds.
(The Motor Relay cycles on/off
once every 30 seconds)
• Check wiring to PCB
• Replace the PCB as necessary
3E2
Motor Relay
Stuck
When the motor state is
"stopped", the control detects
the zero cross motor signal
within 60 seconds.
• Check motor connector and wiring.
• Replace the PCB as necessary
5E
Drain Fail
Water over
fl
ow condition
detected 3 consecutive times.
• Check the water tank & water sensor.
• Check the pump & drain pipe.
• Replace the PCB as necessary.