Condensate Pump
The moisture collected in the condenser area
fl
ows to the pump area. The condensed water can
either be pumped away to a drain line (e.g. into a
standpipe shared with the clothes washer) or stored
in a container within the dryer to be emptied later.
Regardless of the con
fi
guration, the pump and
fl
oat
work the same way.
Under normal conditions, the pump will run for 20
seconds at the beginning of a cycle and 20 seconds
at the end of a cycle, or if excess water accumulates
in the sump area.
The white collar on the
fl
oat switch is magnetic. As
it rises, it trips the contacts in the switch to send a
signal to the control board to activate the pump.
If using the condensation tank:
An over
fi
ll condition
triggered by the
fl
oat switch will cause the pump to
run for 20 seconds. After 4 attempts, if the over
fi
ll
is not cleared, the machine will pause and the
Tank
Full
LED light will illuminate.
The user can press the
START/PAUSE
button to
repeat the above over
fi
ll process. This can be done
unlimited times as long as the over
fi
ll condition still
exists.
Operation of the pump and
fl
oat switch can be
checked by using the service test mode. (See
Service
Test Mode
.)
Speci
fi
c failures associated with the pump and
fl
oat
switch can initiate error code 5E. (See
Error Codes
.)
The condensate pump can be accessed thru the
rear of the dryer.
To remove the condensate pump:
1. Pull to remove grey hose from pump access
cover.
2. Remove 1 Phillips-head screw and pump access
cover.
3. Pull to remove grey hose from pump access
cover.
4. Remove 1 Phillips-head screw and pump cover
from cabinet base.
5. Remove 1 Phillips-head screw that secures the
pump assembly to the base located toward the
middle of the dryer.