![GE DCCH480EK Скачать руководство пользователя страница 33](http://html.mh-extra.com/html/ge/dcch480ek/dcch480ek_technical-service-manual_126183033.webp)
– 33 –
Disconnect
Disconnect
Condensation Tank Housing
Disconnect
4. Disconnect the drum lamp, outlet thermistor,
and touch sensor wire harness and remove it
from the 5 wire retainers.
5. Position the wire harness out of the way.
6. Remove the 3 Phillips-head screws under the
condenser that secure the drum support to the
cabinet.
7. Remove the 4 Phillips-head screws that attach
the drum support to the cabinet.
Foam Air Diverter
Front Air Cover
3. Slide the foam air diverter and front air cover
forward to remove from the dryer.
8. Remove the 3 Phillips-head screws that secure
the condensation tank housing to the cabinet,
and then pull and twist the housing forward
slightly until the housing tab is free from the
frame.
9. Lift the drum support up, pull the bottom out,
and then disengage the drum support tab from
the control panel support bracket.
Control Panel Support Bracket
Tab
Tab