Страница 1: ... of moisture from being blown into the room Before the old dryer is removed from service or discarded remove the dryer door Service information and the wiring diagram are located in the control console Do not allow children on or in the appliance Close supervision of children is necessary when the appliance is used near children NOTE Installation and service of this dryer requires basic mechanical...

Страница 2: ...NG 4 WIRE CONNECTION MUST BE USED FOR MOBILE HOME INSTALLATION This dryer must be connected to an individual branch circuit protected by the required time delay fuses or circuit breakers A four or three wire single phase 120 240V or 120 208V 60Hz 30 amp circuit is required If the electric supply does not meet the above specifications then call a licensed electrician GROUNDING INSTRUCTIONS This dry...

Страница 3: ... THE EXHAUST LENGTH TABLE Using exhaust longer than specified length will Increase the drying times and the energy cost Reduce the dryer life Accumulate lint creating a potential fire hazard The MAXIMUM ALLOWABLE length of the exhaust system depends upon the type of duct number of turns the type of exhaust hood wall cap and all conditions noted below Both rigid and flexible metal duct are shown in...

Страница 4: ...n of lint and grease could create a fire hazard Do not obstruct incoming or exhausted air THIS DRYER COMES READY FOR REAR EXHAUSTING IF SPACE IS LIMITED USE THE INSTRUCTIONS IN SECTION 9 TO EXHAUST DIRECTLY FROM THE SIDES OR BOTTOM OF THE CABINET RECOMMENDED CONFIGURATION TO MINIMIZE EXHAUST BLOCKAGE ELBOW HIGHLY RECOMMENDED ELBOW HIGHLY RECOMMENDED NOTE ELBOWS WILL PREVENT DUCT KINKING AND COLLAP...

Страница 5: ...d If the closet contains both a washer and a dryer doors must contain a minimum of 120 sq in of open area equally distributed OTHER INSTALLATIONS If the installation makes it impossible to exhaust to the outdoors a 4 exhaust deflector WE25X278 must be installed A clearance of 8 is required between the rear of the dryer and the wall and the deflector should be pointing up Installation must conform ...

Страница 6: ... DESIRED KNOCKOUT ONE ONLY FIXING HOLE BEND TAB UP 45 9 A B ADDING NEW DUCT Reconnect the cut portion A of the duct to the blower housing Make sure that the shortened duct is aligned with the tab in the base Use the screw saved previously to secure the duct in place through the tab on the appliance base RIGHT OR LEFT SIDE EXHAUST PORTION A FIXING HOLE o Preassemble 4 elbow with 4 duct Wrap duct ta...

Страница 7: ...ch hinge on the dryer face half way With one hand holding the top of the door and the other hand holding the bottom remove the door from the dryer by lifting it UP and OUT 3 Rotate the door 180º Insert the door on the opposite side of the opening by moving the door IN and DOWN until the top hinge and the bottom hinge are resting on the top screws inserted in step 1 4 Remove the remaining screws fr...