Installation Instructions

1. Turn off the circuit breaker (s) (30 amp) or remove the dryer’s 
    circuit fuse at the electrical box.
2. Be sure the dryer cord is unplugged from the wall.
3. Remove the power cord cover located at the lower back.
4. Install 3/4 in. UL recognized strain relief to power cord 

    

    entry hole. Bring power cord through strain relief.
5. Connect power cord as follows:

A. Connect the 2 hot lines to the outer screws of the 

                    terminal block (marked L1 and L2).

B. Connect the neutral (white) line to the center of 

     the terminal block (marked N).
6. Be sure ground strap is connected to neutral (center) 

    

    terminal of block and to green ground screw on cabinet 
    rear. Tighten all terminal block screws (3) completely.
7. Properly secure power cord to strain relief.
8. Reinstall the cover.

CONNECTING DRYER USING 3-WIRE
CONNECTION

L1

L2

STRAIN RELIEF
BRACKET

3/4", UL
RECOGNIZED
STRAIN RELIEF

HOT
WIRE

HOT
WIRE

GROUND
STRAP 

GREEN
GROUND
SCREW

NEUTRAL
(White)

SCREWS
(3)

IF REQUIRED, BY LOCAL CODE,
INSTALL EXTERNAL GROUND
(NOT PROVIDED) TO GROUNDED
METAL, COLD WATER PIPE, OR
OTHER ESTABLISHED GROUND
DETERMINED BY A QUALIFIED
ELECTRICIAN.

COVER 

3 #10 AWG MINIMUM COPPER
CONDUCTORS OR 120/240V 30A POWER
SUPPLY CORD KIT MARKED FOR USE
WITH DRYERS & PROVIDED WITH CLOSED
LOOP OR SPADE TERMINALS WITH
UPTURNED ENDS (NOT SUPPLIED).

1. Turn off the circuit breaker (s) (30 amp) or remove the dryer’s 
    circuit fuse at the electrical box.
2. Be sure the dryer cord is unplugged from the wall receptacle.
3. Remove the power cord cover located at the lower back.
4. Remove and discard ground strap. Keep the green 

    

    ground screw for step 7.
5. Install 3/4 in. UL recognized strain relief to power 

    

    cord entry hole. Bring power cord through strain relief.
6. Connect power cord as follows:

A. Connect the 2 hot lines to the outer screws of 
     the terminal block (marked L1 and L2). 
B. Connect the neutral (white) line to the center of 

     

    the terminal block (marked N).

7. Attach ground wire of power cord with the green ground 

    

    screw (hole above strain relief bracket). Tighten all 

    

    terminal block screws (3) completely.
8. Properly secure power cord to strain relief.
9. Reinstall the cover.

     WARNING: NEVER LEAVE THE

COVER OFF OF THE TERMINAL BLOCK. 

     WARNING: NEVER LEAVE THE

COVER OFF OF THE TERMINAL BLOCK. 

3  EXHAUST INFORMATION

      WARNING - USE ONLY METAL 4-IN. DUCT.
DO NOT USE DUCT LONGER THAN SPECIFIED
IN THE EXHAUST LENGTH TABLE.

Using exhaust longer than specified length will:

• Increase the drying times and the energy cost.
• Reduce the dryer life.
• Accumulate lint, creating a potential fire hazard.

The MAXIMUM ALLOWABLE length of the exhaust system 
depends upon the type of duct, number of turns, the type of 
exhaust hood (wall cap), and all conditions noted below. Both 
rigid and flexible metal duct are shown in the table below.

The correct exhaust installation is YOUR RESPONSIBILITY.
Problems due to incorrect installation are not covered
by the warranty.

EXHAUST SYSTEM CHECK LIST

EXHAUST LENGTH

4" DIA.

4"

4" DIA.

4" DIA.

2-1/2"

RECOMMENDED MAXIMUM LENGTH

Exhaust Hood Types

Recommended

No. of 90º

Elbows

Flexible

Metal

Rigid

Metal

Rigid

Metal

90 Feet
60 Feet
45 Feet
35 Feet
25 Feet

0
1
2
3
4

55 Feet
40 Feet
30 Feet
20 Feet
15 Feet

60 Feet
45 Feet
35 Feet
25 Feet
15 Feet

45 Feet
30 Feet
20 Feet
15 Feet
10 Feet

Flexible

Metal

Use only for short

run installations

HOOD OR WALL CAP

• Terminate in a manner to prevent back drafts or entry of birds or
  other wildlife.
• Termination should present minimal resistance to the exhaust air flow
  and should require little or no maintenance to prevent clogging.
• 

Never

 install a screen in or over the exhaust duct. This could cause lint build up.

• Wall caps must be installed at least 12 in. above ground level or any other
  obstruction with the opening pointed down.
• If roof vents or louvered plenums are used, they must be equivalent to a
  4-in. dampened wall cap in regard to resistance to air flow, prevention of
  back drafts, and maintenance required to prevent clogging.

SEPARATION OF TURNS

For best performance, separate all turns by at least 4 ft. of straight duct, 
including distance between last turn and exhaust hood.

TURNS OTHER THAN 90º

• One turn of 45º or less may be ignored.
• Two 45º turns should be treated as one 90º turn.
• Each turn over 45º should be treated as one 90º turn.

SEALING OF JOINTS

• All joints should be tight to avoid leaks. The male end of each section of
  duct must point away from the dryer.
• Do not assemble the ductwork with fasteners that extend into the duct.
  They will serve as a collection point for lint.
• Duct joints can be made air and moisture-tight by wrapping the
  overlapped joints with duct tape.
• Horizontal runs should slope down toward the outdoors 1/2 inch per foot

INSULATION

Duct work that runs through an unheated area or is near air conditioning
should be insulated to reduce condensation and lint build-up.

If using flexible metal duct, please refer to page 5.

Содержание DBSR453EBWW

Страница 1: ... of moisture from being blown into the room Before the old dryer is removed from service or discarded remove the dryer door Service information and the wiring diagram are located in the control console Do not allow children on or in the appliance Close supervision of children is necessary when the appliance is used near children NOTE Installation and service of this dryer requires basic mechanical...

Страница 2: ...NG 4 WIRE CONNECTION MUST BE USED FOR MOBILE HOME INSTALLATION This dryer must be connected to an individual branch circuit protected by the required time delay fuses or circuit breakers A four or three wire single phase 120 240V or 120 208V 60Hz 30 amp circuit is required If the electric supply does not meet the above specifications then call a licensed electrician GROUNDING INSTRUCTIONS This dry...

Страница 3: ... THE EXHAUST LENGTH TABLE Using exhaust longer than specified length will Increase the drying times and the energy cost Reduce the dryer life Accumulate lint creating a potential fire hazard The MAXIMUM ALLOWABLE length of the exhaust system depends upon the type of duct number of turns the type of exhaust hood wall cap and all conditions noted below Both rigid and flexible metal duct are shown in...

Страница 4: ...n of lint and grease could create a fire hazard Do not obstruct incoming or exhausted air THIS DRYER COMES READY FOR REAR EXHAUSTING IF SPACE IS LIMITED USE THE INSTRUCTIONS IN SECTION 9 TO EXHAUST DIRECTLY FROM THE SIDES OR BOTTOM OF THE CABINET RECOMMENDED CONFIGURATION TO MINIMIZE EXHAUST BLOCKAGE ELBOW HIGHLY RECOMMENDED ELBOW HIGHLY RECOMMENDED NOTE ELBOWS WILL PREVENT DUCT KINKING AND COLLAP...

Страница 5: ...d If the closet contains both a washer and a dryer doors must contain a minimum of 120 sq in of open area equally distributed OTHER INSTALLATIONS If the installation makes it impossible to exhaust to the outdoors a 4 exhaust deflector WE25X278 must be installed A clearance of 8 is required between the rear of the dryer and the wall and the deflector should be pointing up Installation must conform ...

Страница 6: ... DESIRED KNOCKOUT ONE ONLY FIXING HOLE BEND TAB UP 45 9 A B ADDING NEW DUCT Reconnect the cut portion A of the duct to the blower housing Make sure that the shortened duct is aligned with the tab in the base Use the screw saved previously to secure the duct in place through the tab on the appliance base RIGHT OR LEFT SIDE EXHAUST PORTION A FIXING HOLE o Preassemble 4 elbow with 4 duct Wrap duct ta...

Страница 7: ...ch hinge on the dryer face half way With one hand holding the top of the door and the other hand holding the bottom remove the door from the dryer by lifting it UP and OUT 3 Rotate the door 180º Insert the door on the opposite side of the opening by moving the door IN and DOWN until the top hinge and the bottom hinge are resting on the top screws inserted in step 1 4 Remove the remaining screws fr...

Страница 8: ...Notes ...

Отзывы: