GE DBSR453EBWW Скачать руководство пользователя страница 5

5

Installation Instructions, Indoor Exhausting

6  ALCOVE OR CLOSET INSTALLATION

7  BATHROOM OR BEDROOM
INSTALLATION

8  MOBILE OR MANUFACTURED
HOME INSTALLATION

If rigid all-metal duct cannot be used, then flexible all-metal ducting 
can be used, but it will reduce the maximum recommended duct 
length. In special installations when it is impossible to use only 
metal ducting, then UL-listed clothes dryer flexible metal transition 
duct may be used as transition venting between the dryer and wall 
connection only. The use of this ducting will affect dry time.

If flexible transition duct is necessary, the following directions 

must

 

     

 

be followed.

• Use the Shortest Length Possible.
• Stretch the Duct to Its Maximum Length to avoid kinks.
• Do Not Crush or Collapse the Duct.
• Never Use Transition Duct Inside the Wall or
  Inside the Dryer.
• Avoid Resting the Duct on Sharp Objects.
• 

Venting Must Conform to Local Building Codes.

              

USING FLEXIBLE METAL DUCTS

• If your dryer is approved for installation in an alcove or 
  closet, it will be stated on a label on the dryer back.
• The dryer MUST be vented to the outdoors. See the 
  EXHAUST INFORMATION sections 3 & 4. 
• Minimum clearance between dryer cabinet and adjacent       
  walls or other surfaces is:

0 in. either side
3 in. front and rear

• Minimum vertical space from floor to overhead cabinets, 
  ceiling, etc. is 52 in.
• Closet doors must be louvered or otherwise ventilated and 
  must contain a minimum of 60 sq. in. of open area equally 
  distributed. If the closet contains both a washer and a 
  dryer, doors must contain a minimum of 120 sq. in. of open 
  area equally distributed.

OTHER INSTALLATIONS: If the installation makes it 
impossible to exhaust to the outdoors, a 4" exhaust 
deflector (WE25X278) must be installed. A clearance of 8" 
is required between the rear of the dryer and the wall, and 
the deflector should be pointing up.

• Installation must conform to the MANUFACTURED 
  HOME CONSTRUCTION & SAFETY STANDARD, 
  TITLE 24, PART 32-80 or, when such standard is not 
  applicable, with AMERICAN NATIONAL STANDARD 
  FOR MOBILE HOME, ANSI/NFPA NO. 501B.
• The dryer MUST be vented to the outdoors with the 
  termination securely fastened to the mobile home 
  structure. (See EXHAUST INFORMATION
  section 3 & 4.)
• The vent MUST NOT be terminated beneath a mobile or 
  manufactured home.
• The vent duct material MUST BE METAL.
• Do not use sheet metal screws or other fastening  devices 
  which extend into the interior of the exhaust vent.
• See section 2 for electrical connection information.

INDOOR EXHAUSTING

NOTE: MOBILE HOME, BEDROOM, BATHROOM,
ALCOVE OR CLOSET INSTALLATIONS
MUST BE EXHAUSTED TO THE OUTDOORS

NOTE: EXHAUSTING TO THE OUTDOORS IS
STRONGLY RECOMMENDED, EXHAUSTING
INDOORS MAY CAUSE LINT ACCUMULATION,
AND MOISTURE DAMAGE INCLUDING MOLD
AND MILDEW.

ELBOWS HIGHLY
RECOMMENDED

ELBOW HIGHLY
RECOMMENDED

DO NOT
SIT DRYER
ON FLEXIBLE
EXHAUST.

DO NOT USE
EXCESSIVE
EXHAUST
LENGTH

DO NOT
CRUSH
FLEXIBLE
EXHAUST
AGAINST
WALL.

DO

DON’T

• The dryer MUST be vented to the outdoors. See 
  EXHAUST INFORMATION section 3 & 4.
• The installation must conform with local codes or, in the 
  absence of local codes, with the NATIONAL  ELECTRI-     
  CAL CODE, ANSI/NFPA NO. 70.

Содержание DBSR453EBWW

Страница 1: ... of moisture from being blown into the room Before the old dryer is removed from service or discarded remove the dryer door Service information and the wiring diagram are located in the control console Do not allow children on or in the appliance Close supervision of children is necessary when the appliance is used near children NOTE Installation and service of this dryer requires basic mechanical...

Страница 2: ...NG 4 WIRE CONNECTION MUST BE USED FOR MOBILE HOME INSTALLATION This dryer must be connected to an individual branch circuit protected by the required time delay fuses or circuit breakers A four or three wire single phase 120 240V or 120 208V 60Hz 30 amp circuit is required If the electric supply does not meet the above specifications then call a licensed electrician GROUNDING INSTRUCTIONS This dry...

Страница 3: ... THE EXHAUST LENGTH TABLE Using exhaust longer than specified length will Increase the drying times and the energy cost Reduce the dryer life Accumulate lint creating a potential fire hazard The MAXIMUM ALLOWABLE length of the exhaust system depends upon the type of duct number of turns the type of exhaust hood wall cap and all conditions noted below Both rigid and flexible metal duct are shown in...

Страница 4: ...n of lint and grease could create a fire hazard Do not obstruct incoming or exhausted air THIS DRYER COMES READY FOR REAR EXHAUSTING IF SPACE IS LIMITED USE THE INSTRUCTIONS IN SECTION 9 TO EXHAUST DIRECTLY FROM THE SIDES OR BOTTOM OF THE CABINET RECOMMENDED CONFIGURATION TO MINIMIZE EXHAUST BLOCKAGE ELBOW HIGHLY RECOMMENDED ELBOW HIGHLY RECOMMENDED NOTE ELBOWS WILL PREVENT DUCT KINKING AND COLLAP...

Страница 5: ...d If the closet contains both a washer and a dryer doors must contain a minimum of 120 sq in of open area equally distributed OTHER INSTALLATIONS If the installation makes it impossible to exhaust to the outdoors a 4 exhaust deflector WE25X278 must be installed A clearance of 8 is required between the rear of the dryer and the wall and the deflector should be pointing up Installation must conform ...

Страница 6: ... DESIRED KNOCKOUT ONE ONLY FIXING HOLE BEND TAB UP 45 9 A B ADDING NEW DUCT Reconnect the cut portion A of the duct to the blower housing Make sure that the shortened duct is aligned with the tab in the base Use the screw saved previously to secure the duct in place through the tab on the appliance base RIGHT OR LEFT SIDE EXHAUST PORTION A FIXING HOLE o Preassemble 4 elbow with 4 duct Wrap duct ta...

Страница 7: ...ch hinge on the dryer face half way With one hand holding the top of the door and the other hand holding the bottom remove the door from the dryer by lifting it UP and OUT 3 Rotate the door 180º Insert the door on the opposite side of the opening by moving the door IN and DOWN until the top hinge and the bottom hinge are resting on the top screws inserted in step 1 4 Remove the remaining screws fr...

Страница 8: ...Notes ...