Section 2 - Installation
9
2.2.4 Internal Jumper Location
Figure 2.1 shows the location of the jumpers on the monitor's circuit board.
To set the jumpers follow these steps:
1. Remove the case cover: Pull the case cover straight up. The inside of the case
cover has a label that summarizes the jumper settings.
2. Locate the five jumpers along the side of the top board (see Figure 2-1).
Figure 2-1: Location of internal jumpers.
3. Remove or insert any of the jumpers that are required for your given
application.
4. Snap the case cover back into place over the printed circuit boards.
2.3 Monitor Enclosure
Use
a
TYPE
4X
enclosure
for
outdoor
and
Class
1, Division
2
hazardous
areas.
If
the
monitor
will
be
in
a nonhazardous location where it is protected from the
elements, then a weatherproof enclosure is not required. Bently Nevada offers a
nonmetallic Type 4X enclosure (Bently Nevada Part Number 190100-01) or a
stainless steel RFI resistant Type 4X enclosure (Bently Nevada Part Number
03636315) for 1900 monitors. Both have windows on the front so that the LCD
display of the monitor is visible from outside the enclosure. Appendix D provides
ordering information. For more information on Bently Nevada's Type 4X enclosures
for the 1900 monitor, contact your local Bently Nevada sales representative.