Technical Specifications
Steady State Gas
Consumption
<10 scfh when bleeding to atmosphere
When bleeding downstream, see
consumption table in Appendix
Supply Gas
Dry, filtered (100 micron) gas
Maximum Flow Capacity
850 scfh (24 scmh)
Maximum Supply Pressure
400 psig (2758 kPa)
Maximum Supply –
Discharge Differential
150 psig (1034 kPa)
Minimum Supply –
Discharge Differential
50 psig (348 kPa)
Operative Ambient
Temperature Range
-20°F to 160°F
(-29°C to 71°C)
Approximate Weight
12 pounds (5.4 kg)
Minimum Deadband
0.2% instrument signal
Control Accuracy
± 0.75% of setpoint
Maximum Sensing Pressure
1500 psig
Setpoint Range
3 psig – 1500 psig
21 kPa – 10342 kPa
Housing
Meets NEMA 3 classification
Installation Orientation
Vertical position recommended
• Custom bracket supplied with
Becker Actuators
• 2-in pipe mount provided for retrofit to
other manufacturers’ actuators
Materials of Construction
External Parts
AL 2024 Anodized Aluminium/316
Stainless Steel
Internal Parts
316 Stainless Steel/2024 Anodized Aluminum
Springs
Plated steel
Diaphragms
Buna-N with nylon reinforcement
Seats and O-Rings
Buna-N
Tubing and
Tubing Fittings
316 Stainless Steel
Gauges
2-1/2 inch dial liquid filled brass connection w/
stainless steel case
(1)
(standard issue with units of psig dual units of
psig/kPa available).
(1)
Consult GE for additional information.
Model Number Explanation
• The VRP-B-CH pilot is available in four different models to
cover sensing pressures from 3 psig to 1500 psig.
• The number expressed in the VRP model designation is the
maximum sensing pressure (for example, a VRP-B-600-CH
has a maximum sensing pressure of 600 psig).
Identification Tag
Each unit has a stainless steel control tag fastened under one of
the bolts of the spring cartridge. The range of the control spring
is stamped on the face side of the tag. The shipping date and
seven-character part number are stamped on the bottom side
of the tag. The letter after the seven-digit part number identify
the pilot revision series.
VRP-B-175-CH
VRP-B-600-CH
VRP-B-CH pilots – model numbers
VRP-B-1000-CH
VRP-B-1500-CH