background image

Consumer Support

Tr

oubleshooting T

ips

Operating Instructions

Safety Instructions

Installation Instructions

6

ON/OFF Switch

Turns air conditioner on and off.

NOTE:

If the air conditioner is off and is then turned on while

set in a 

Cool

mode, it will take approximately 3 minutes for

the compressor to start and cooling to begin.

Fan Switch 

(on some models)

Use to set the fan speed to 

LO

or 

HI

.

Mode/Temp Control

Use to set the air conditioner to the 

Fan Only

or a

Cool

mode.

Fan Only Mode

Use 

Fan Only

at 

HI

or 

LO Fan

to provide air

circulation and filtering without cooling.

Cool Mode

Use a 

Cool

setting with 

HI

or 

LO Fan

for cooling.

Turn the knob clockwise, toward the larger blue
area, for the indoor area to become cooler. Turn
the knob counterclockwise, toward the smaller blue 

area, for the indoor air to become warmer. 
The Mode/Temp control is used to maintain the
room temperature. When set in a 

Cool

mode, the

compressor will cycle on and off to keep the room
at the same level of comfort.

Cooling Descriptions

For Normal Cooling—

Select a 

Cool 

mode with the

Mode/Temp knob set at the midpoint.

For Maximum Cooling—

Select a 

Cool 

mode with 

the Mode/Temp knob set toward the larger 
blue area.

For Quieter & Nighttime Cooling—

Select a 

Cool 

mode with

the Mode/Temp knob set toward the smaller blue area.

NOTE: 

If you move the Mode/Temp control knob from a

Cool

setting to the 

Fan Only

setting, wait at least 3 minutes

before switching back to a 

Cool

setting.

About the controls on the air conditioner—models with control knob(s).

Features and appearance may vary.

Controls 

(on models so equipped)

Controls 

(on models so equipped)

Mode Control

Hi Cool, Med Cool

and 

Low Cool

provide cooling

with different fan speeds.

Low Fan

or 

Hi Fan

provides air circulation and

filtering without cooling.

Thermostat Control

The thermostat control is used to maintain the
room temperature. The compressor will cycle on
and off to keep the room at the same level of
comfort. When you turn the knob to a higher
number, the indoor air will become cooler. Turn
the knob to a lower number and the indoor air
will become warmer.

NOTE: 

If you move the switch from a cool setting to 

OFF

or 

to a fan setting, wait at least 3 minutes before switching back to a
cool setting.

Cooling Descriptions

For Normal Cooling

–Select 

Hi Cool

or 

Med Cool

with the

thermostat control at midpoint.

For Maximum Cooling

–Select 

Hi Cool

with the thermostat

control at the highest number available on your knob.

For Quieter & Nighttime Cooling

–Select 

Low Cool

with the

thermostat control at midpoint.

Содержание ASM06

Страница 1: ...t Registration 15 16 Warranty 17 DB98 26674A 49 7552 1 12 06 JR ASM05 ASQ05 ASS05 ASV05 ASM06 ASQ06 ASV06 ASQ08 ASV08 Air Conditioners Owner s Manual and Installation Instructions ge com Write the mod...

Страница 2: ...law must be removed prior to product disposal If you are getting rid of an old product with refrigerants check with the company handling disposal about what to do SAFETY PRECAUTIONS Do not under any...

Страница 3: ...must use an extension cord it is absolutely necessary that it be a UL listed 14 gauge 3 wire grounding type appliance extension cord having a grounding type plug and outlet and that the electrical ra...

Страница 4: ...Energy Saver Controls the fan On The fan and compressor cycle on and off This results in wider variations of room temperature and humidity Normally used when the room is unoccupied Note The fan will...

Страница 5: ...e Cool mode and High 3 or Med 2 fan with a middle set temperature For Maximum Cooling Select the Cool mode and High 3 fan with a lower set temperature For Quieter Nighttime Cooling Select the Cool mod...

Страница 6: ...rd the larger blue area For Quieter Nighttime Cooling Select a Cool mode with the Mode Temp knob set toward the smaller blue area NOTE If you move the Mode Temp control knob from a Cool setting to the...

Страница 7: ...on is adjusted by the louver levers Vent Control on some models The vent control is located on the inside of the air louvers in the lower right corner When set at CLOSE only the air inside the room wi...

Страница 8: ...attery cover by sliding it according to the arrow direction Insert new batteries making sure that the and of battery are installed correctly Reattach the cover by sliding it back into position NOTES U...

Страница 9: ...he possibility of electric shock hazard If the wall outlet you plan to use is only a 2 prong outlet it is your responsibility to have it replaced with a properly grounded 3 prong wall outlet Some mode...

Страница 10: ...DED Appearance may vary Type A 9 or 10 1 2 Screws Security bracket 3 Type B 7 3 4 Screws Top mounting rail Right accordion panel Foam top window gasket Window sash seal Left accordion panel Air condit...

Страница 11: ...RM WINDOW REQUIREMENTS A storm window frame will not allow the air conditioner to tilt toward the outside and will keep it from draining properly To adjust for this attach a piece of wood to the stool...

Страница 12: ...the accordion panels to the side of the case using 6 type A screws 3 D Top mounting rail Accordion panels Installation Instructions 4 A Window sash seal B INSTALL AIR CONDITIONER IN WINDOW CONT Extend...

Страница 13: ...an the filter at least every 30 days See the Operating Instructions section The room may have been hot When the air conditioner is first turned on you need to allow time for the room to cool down Cold...

Страница 14: ...14 Consumer Support Troubleshooting Tips Operating Instructions Safety Instructions Installation Instructions Notes...

Страница 15: ...tection or you may request your money back on the remaining value of your contract No questions asked It s that simple Protect your refrigerator dishwasher washer and dryer range TV VCR and much more...

Страница 16: ...t here Complete and mail your Consumer Product Ownership Registration today Have the peace of mind of knowing we can contact you in the unlikely event of a safety modification After mailing the regist...

Страница 17: ...ed after delivery Product not accessible to provide required service What Is Not Covered This warranty is extended to the original purchaser and any succeeding owner for products purchased for home us...

Страница 18: ...that are available while your warranty is still in effect You can purchase it on line anytime or call 800 626 2224 during normal business hours GE Consumer Home Services will still be there after you...

Страница 19: ...dor Apoyo al consumidor 18 Garant a 17 DB98 26674A 49 7552 1 12 06 JR ASM05 ASQ05 ASS05 ASV05 ASM06 ASQ06 ASV06 ASQ08 ASV08 Acondicionadores de Aire Manual del Propietario e Instrucciones de Instalaci...

Страница 20: ...deben ser removidos antes de desecharlos Si usted planea deshacerse de alg n producto que contenga refrigerantes p ngase en contacto con la compa a que se encarga de recoger su basura para que le indi...

Страница 21: ...si usted se ve en la necesidad de usar un cable el ctrico de extensi n es absolutamente necesario que el mismo est listado bajo UL calibre 14 de tipo 3 tomas con conexi n a tierra para electrodom stic...

Страница 22: ...uando la habitaci n no est ocupada Nota El ventilador continuar funcionando por un corto tiempo despu s de que el compresor haya entrado en el ciclo de apagado Off Apagado El ventilador funciona todo...

Страница 23: ...6 F en incrementos de 1 F Se usa un termostato para mantener la temperatura de la habitaci n El compresor har ciclo entre apagado y encendido para mantener la habitaci n a la temperatura deseada Ajust...

Страница 24: ...ciones de enfriamiento Para enfriamiento normal Seleccione un modo Cool Enfriado con el bot n Mode Temp en la posici n del centro Para enfriamiento m ximo Seleccione un modo Cool Enfriado con el bot n...

Страница 25: ...as El control de ventilaci n est localizado al interior de las persianas en la esquina derecha inferior Cuando est ajustado en CLOSE CERRADO solamente el aire en el interior de la habitaci n circular...

Страница 26: ...la de acuerdo con la direcci n de la flecha Inserte bater as nuevas cercior ndose de que los polos positivos y negativos est n orientados correctamente Coloque la cubierta otra vez desliz ndola en su...

Страница 27: ...planea usar solamente tiene 2 tomas es su responsabilidad hacer que un t cnico lo reemplace por uno de tres tomas con conexi n a tierra REQUISITOS ELECTRICOS Algunos modelos requieren 230 208 voltios...

Страница 28: ...erior de espuma de la ventana Sello del marco de la ventana Panel de acorde n izquierdo Tornillos 3 4 tipo B 7 Soporte de seguridad 3 Cinta de sellado del riel de montaje superior Tornillos 1 2 tipo A...

Страница 29: ...SV05 ASQ06 y ASV06 131 2 m n 241 2 a 36 con paneles de acorde n 11 REQUISITOS DE UNA VENTANA DE TORMENTAS Un marco de ventana de tormentas no permitir que el acondicionador de aire se incline hacia el...

Страница 30: ...e de seguridad Soporte de seguridad 12 PREPARE EL ACONDICIONADOR DE AIRE CONT Inserte los marcos de los paneles de acorde n en la parte superior e inferior de los rieles de montaje Adhiera los paneles...

Страница 31: ...n cada lado del acondicionador de aire 4 C Tornillos tipos B Tornillo tipo B Tornillos tipos B INSTALE EL SOPORTE DE SEGURIDAD Y LA PARTE SUPERIOR DE LA ESPUMA DE LA JUNTA DE LA VENTANA Pegue el sopor...

Страница 32: ...e est escapando Cerci rese de que los registros de la calefacci n no est n abiertos y se encuentran retornando el aire fr o Coloque la ventanilla del acondicionador de aire en la posici n cerrada Las...

Страница 33: ...ndensador en los d as lluviosos o cuando la humedad es alta Esta caracter stica de dise o ayuda a remover la humedad y mejora la eficiencia Quiz s escuche que el termostato hace clic cuando el compres...

Страница 34: ...16 Notas Apoyo al consumidor Soluci n de problemas Instrucciones de operaci n Instrucciones de seguridad Instrucciones de instalaci n...

Страница 35: ...oducto no accesible para facilitar el servicio requerido Lo que no est cubierto Esta garant a se extiende al comprador original y cualquier comprador posterior de productos comprados para uso residenc...

Страница 36: ...e comprarla en l nea en cualquier momento o llamar al 800 626 2224 durante horas normales de oficina GE Consumer Home Services estar a n ah cuando su garant a termine Piezas y accesorios ge com Aquell...

Отзывы: