Installation Guide

8

AC line

Use proper circuit 

protection level

3

1

2

Connect the green wire 

to the incoming ground 

conductor. Connect the black 

wire to Line 1 and white 

wires to Neutral or Line 2 of 

the incoming AC line.

Lightbar

Lightbar

AC line

To driver 

input

Male

Lightbar

Secure locknut

Driver

Female

Mate male connector from lightbar with female connector from DC output of 

driver. Ensure matching up the key guides from Male to Female connector.

Driver Output and Lightbar Electrical Connections

Connection Schematic

1

2

DO NOT MAKE OR BREAK ELECTRICAL CONNECTION WHILE POWER IS APPLIED.

Driver Input  Wire Colors
Black = Line 1
White = Neutral or Line 2
Yellow/Green = Ground

Optional 3’or 6’ interconnection cable

NOTE: Maximum cumulative length of 

interconnection cable is 6 feet.

 

WARNING / AVERTISSEMENT

RISK OF ELECTRIC SHOCK OR PRODUCT DAMAGE

Turn power OFF before inspection, installation or removal.

RISQUE DE CHOC ÉLECTRIQUE OU DE DOMMAGE AU PRODUIT

Coupez l’alimentation avant l’inspection, l’installation ou la désinstallation.

Key

Содержание Arize Factor

Страница 1: ...longevity of the luminaire ensure that the lightbar and driver are clean and free of dirt dust oil or any other debris Do not apply any kind of film on the lens or otherwise cover the driver or light...

Страница 2: ...77 347VAC 2 5 2A GEPSC210 600G AGJNA D17A1 NEMA L7 15P 3 48 kg 7 33lbs 277 VAC 2 5A Product Code Detailed Description Weight Series Load per Driver System Watts per Lightbar GEHF HPKRW1 ML900 PKR 2 6...

Страница 3: ...etween Lightbars 15 Mounting Accessories SKU Description Detailed Description Weight 95051690 GEMB BANE Factor suspended mount wireform support 0 012 kg 0 026lbs 95051689 GEMB BAW1 Factor rolling rack...

Страница 4: ...wo screws located at each end of the bracket After the horizontal bracket is attached to the strut secure the bracket to the struts by tightening the two screws located each end of the bracket ML300 R...

Страница 5: ...Series lightbar can suspended on a support structure A or on cables as shown above B and C Attach wireform supports by pushing up into the slots on the underside of the lightbar A Adjust screws to le...

Страница 6: ...he screws shown Components required GEHAK NN NE N0 Driver universal 1 remote mount kit 95047411 2 required Insert each toggle into the hole in the top of each driver bracket Wrap the two toggle cables...

Страница 7: ...be secured such that it does not touch the light bar Shorting Cap Installation ML900 Electrical Connection 2 Lightbars only ML 300 Electrical connection 4 5 or 6 Lightbars only For all configurations...

Страница 8: ...e key guides from Male to Female connector Driver Output and Lightbar Electrical Connections Connection Schematic 1 2 DO NOT MAKE OR BREAK ELECTRICAL CONNECTION WHILE POWER IS APPLIED Driver Input Wir...

Страница 9: ...Replacement Ensure gasket is sitting in place on the inner edge of the junction box cover Fasten all 6 screws to ensure water tight seal NOTE Be careful not to strip out the junction box enclosure by...

Страница 10: ...dress these risks at the facility level and to ensure that people entering the plant growth areas while the lights are on are aware of these risks and that appropriate safeguards are in place Ces aver...

Отзывы: