background image

Arize

®

 Factor 

Installation Guide

9

Wired Dimming Connections (Optional)

Junction Box Cover Removal
•  Using a #1 Phillips screwdriver, unscrew the 6 

screws on the junction box cover. 

•  Remove the junction box cover from the junction 

box enclosure.

NOTE: Be sure to hold on to the screws, junction box 

cover, and gasket for future use.

Wall Dimming Wire Insertion
•  Remove the sealed gland in the bottom of the 

junction box enclosure, and install an appropriate 

Listed ½” NPT fitting rated for the environment into 

the open threaded open conduit connection.

•  Bring the conductors for the building dimming 

network into this fitting.

NOTE: Customer is responsible for the 1/2'' NPT- 14 

thread per inch fitting.

Wire Dimming Electrical Connection
Connect the appropriate wiring to Dim + (0-10V) and 

Dim - (0-10V) from driver. Insulate the black, pink & 

blue wires. Follow dimming switch instructions for rest 

of connection.

Junction Box Cover Replacement 
•   Ensure gasket is sitting in place on the inner edge of 

the junction box cover.

•   Fasten all 6 screws to ensure water tight seal.
NOTE: Be careful not to strip out the junction box 

enclosure by over tightening the screws.

Driver

Dimming 

Switch

Violet

Blue

Pink

Black

Gray

+ (0-10V)

- (0-10V)

Gasket in cover

1

3

2

4

Remove cover

Dimming In

To lightbar

AC input

Remove screws

 

WARNING / AVERTISSEMENT

RISK OF ELECTRIC SHOCK OR PRODUCT DAMAGE

•  Turn power off before installation, inspection, cleaning or 

removal. Follow appropriate lock out/tag out safety procedure.

•  This product must be installed in accordance with the 

applicable installation code by a person familiar with 

the construction and operation of the product and the 

hazards involved.

RISQUE DE CHOC ÉLECTRIQUE OU DE DOMMAGE AU PRODUIT

•  Coupez l’alimentation avant l’inspection, l’installation ou la 

désinstallation. Suivez la procédure de sécurité appropriée de verrouillage/

étiquetage.

•  Ce produit doit être installé selon le code d’installation 

pertinent, par une personne qui connaît bien le produit et son 

fonctionnement ainsi que les risques inhérents.

Содержание Arize Factor

Страница 1: ...longevity of the luminaire ensure that the lightbar and driver are clean and free of dirt dust oil or any other debris Do not apply any kind of film on the lens or otherwise cover the driver or light...

Страница 2: ...77 347VAC 2 5 2A GEPSC210 600G AGJNA D17A1 NEMA L7 15P 3 48 kg 7 33lbs 277 VAC 2 5A Product Code Detailed Description Weight Series Load per Driver System Watts per Lightbar GEHF HPKRW1 ML900 PKR 2 6...

Страница 3: ...etween Lightbars 15 Mounting Accessories SKU Description Detailed Description Weight 95051690 GEMB BANE Factor suspended mount wireform support 0 012 kg 0 026lbs 95051689 GEMB BAW1 Factor rolling rack...

Страница 4: ...wo screws located at each end of the bracket After the horizontal bracket is attached to the strut secure the bracket to the struts by tightening the two screws located each end of the bracket ML300 R...

Страница 5: ...Series lightbar can suspended on a support structure A or on cables as shown above B and C Attach wireform supports by pushing up into the slots on the underside of the lightbar A Adjust screws to le...

Страница 6: ...he screws shown Components required GEHAK NN NE N0 Driver universal 1 remote mount kit 95047411 2 required Insert each toggle into the hole in the top of each driver bracket Wrap the two toggle cables...

Страница 7: ...be secured such that it does not touch the light bar Shorting Cap Installation ML900 Electrical Connection 2 Lightbars only ML 300 Electrical connection 4 5 or 6 Lightbars only For all configurations...

Страница 8: ...e key guides from Male to Female connector Driver Output and Lightbar Electrical Connections Connection Schematic 1 2 DO NOT MAKE OR BREAK ELECTRICAL CONNECTION WHILE POWER IS APPLIED Driver Input Wir...

Страница 9: ...Replacement Ensure gasket is sitting in place on the inner edge of the junction box cover Fasten all 6 screws to ensure water tight seal NOTE Be careful not to strip out the junction box enclosure by...

Страница 10: ...dress these risks at the facility level and to ensure that people entering the plant growth areas while the lights are on are aware of these risks and that appropriate safeguards are in place Ces aver...

Отзывы: