30
-
Operating Procedures / Photos
Disassemble Supporting Plate of Motor Support
Use screwdriver to screw off the screws
connecting the supporting plate of motor
support and the rear side plate sub-assy with
the motor support. (Fig 8-22)
Tapping Screw
(Fig 8-22)
Disassemble Left and Right Mounting Plates
Use tool to remove the bolts (2 X M8, 2 X M6)
fixing the left and right mounting plates. (Fig.
8-23)
Mounting Plate
M8 Bolt M6 Bolt
(Fig 8-23)
Disassemble Motor Support
Use screwdriver to screw off the screws at the
rear support base plate and at the both sides
of the support as shown in the figure to remove
the motor support. (refer to Fig. 8-24
、
8-25).
(Fig 8-24)
Screw
(Fig 8-25)