Controller and Remote Controller Function Manua
l
7.1.1 Temperature Parameters
Indoor preset temperature (T
preset
)
Indoor ambient temperature (T
amb.
)
Outdoor condenser temperature (T
cond.
)
7.1.2
Basic Functions
Once started under any mode, the compressor will not be stopped within 6 minutes with the change of ambient
temperature. Once stopped, it cannot be restarted unless after 3-minute lag.
7.1.2.1
Cooling Mode
When
T
amb.
≥
T
preset
+1
℃
, the unit will run under cooling mode, in which case the compressor and outdoor fan will be
started, the indoor fan will run at preset speed and the swing will run as preset.
When
T
amb.
≤
T
preset
-1
℃
, the compressor and outdoor fan will be stopped and the indoor fan will run at preset speed.
When
T
preset
-1
℃
<T
amb.
< T
preset
+1
℃
, the unit will maintain its original operating status.
Under cooling mode, the temperature can be set within a range from 16 to 30
℃
. The initial value is 25
℃
.
T
amb
Start cooling
Maintain original operating status
6 min. 3 min. 6 min. Stop cooling
Compressor
Outdoor fan
Indoor fan
Run at preset speed
Run Stop
7.1.2.2 Dehumidifying Mode
When
T
amb.
≥
T
preset
+2 , the unit will run under coo
℃
ling mode, in which case the compressor and outdoor fan will be
started, the indoor fan will run at low speed.
When
T
preset
-2
≤
T
℃
amb.
≤
T
preset
+2 , the compressor, indoor unit and outdoor unit will run 6 minutes and stop 4
℃
minutes in repeated cycle, while the indoor fan will run at low speed.
When
T
amb.
< T
preset
-2 , the compressor and outdoor fan will be stopped, and the indoor ran will keep running at low
℃
speed.
¾
Under dehumidifying mode, the temperature can be set within a range from 16 to 30 . The init
℃
ial value is 25 .
℃
T
amb
Start cooling
Run under dehumidifying mode
6 min. 4 min. 6 min. 4 min. Stop cooling
Compressor
Outdoor fan
Indoor fan
Low speed
Run Stop
Содержание AIR F24
Страница 2: ... 2 ...
Страница 3: ... 3 ...
Страница 5: ... 5 M Mo od de el l R Re em ma ar rk ks s GE AIR F34 3PH 400V 50Hz R407C ...
Страница 6: ... 6 M Mo od de el l R Re em ma ar rk ks s GE AIR F41 3PH 400V 50Hz R407C ...
Страница 12: ... 12 Applicable to GE AIR F34 IN GE AIR F41 IN ...
Страница 14: ... 14 Applicable to GE AIR F41 OUT Unit mm Bolt Nut Wrench ...
Страница 16: ... 16 GE AIR F24 GE AIR F34 6 6 E El le ec ct tr ri ic ca al l D Di ia ag gr ra am m ...