E
NGINE
P
RESSURE
R
ATIO
(EPR)
K0553 Revision D
86
[EN] English
Engine Pressure Ratio (EPR)
Engine Pressure Ratio (EPR) is sold as a software product option. Contact GE for more details.
The ADTS may be used to check EPR sensors and indicators. Use Ps (static) for INLET pressure
and Pt (Pitot) for OUTLET pressure.
To carry out an EPR check, the display must be showing units of pressure measurement e.g.
mbar, inHg.
NOTE
:
Altitude correction applies to EPR values, make sure this correction does not adversely affect
accuracy. The difference in height between the ADTS and the EPR sensor may be different to the
altitude correction previously set for the aircraft instruments.
The EPR function can be operated using one of two methods, as follows:
1)
Direct control of Inlet pressure and target EPR value (outlet pressure is auto-set).
2)
Direct control of Inlet and Outlet pressure (equivalent EPR aim is auto-set).
The actual method to be used will be specified in the aircraft maintenance manual.
NOTE
: The EPR function can only be launched when you have selected ‘Go to Ground’ and the
ADTS is at Ground Pressures.
Setting the EPR - method 1
1)
On the “Dashboard”, select “EPR”. The EPR control screen appears.
2)
On the EPR control screen, set the toggle control (1) for direct control of Inlet pressure and
target EPR value.
Содержание ADTS552F
Страница 19: ...Chapter 1 Introduction...
Страница 30: ...DUAL HAND TERMINAL EN English 19 K0553 Revision D Figure 1 8 ADTS Touch Slave...
Страница 31: ...Chapter 2 Installation...
Страница 34: ...PACKING FOR STORAGE OR TRANSPORTATION EN English 24 K0553 Revision D...
Страница 40: ...Chapter 3 Operation...
Страница 114: ...Chapter 4 Calibration...
Страница 123: ...Chapter 5 Maintenance...
Страница 132: ...Chapter 6 Testing and Fault Finding...
Страница 152: ...Chapter 7 Specification...