Specifications and Ordering Information
Part Number 141535-01
Rev. E (10/08)
Page 4 of 11
input signal has an upper limitation of
approximately 20 KHz.
Filter quality
Spike high-pass
6-pole Elliptic (155 dB per decade,
minimum). Corner frequency is -
0.1 dB.
Element
bandpass
8-pole Butterworth (155 dB per
decade minimum). Corner
frequency is -3 dB.
Rotor low-pass
6-pole Elliptic (155 dB per decade,
minimum). Corner frequency is -
0.1 dB.
Rotor, Direct
high-pass
1-pole Butterworth (18 dB per
decade, minimum). Corner
frequency is -3 dB.
Spike, Direct
low-pass
Corner is -0.3 dB maximum.
Gap low-pass
1-pole Butterworth (18 dB per
decade, minimum). Corner
frequency is -3 dB.
1X amplitude
Constant Q of 16.67. Stopband
frequencies are 0.91 and 1.09
times the running speed.
Stopband attenuation is -51 dB
minimum.
Accuracy
Amplitude
Within ± 0.33% of full scale
typical, ± 1% maximum when
input signal is at the center
frequency of the proportional
value's passband.
Phase
3 degrees error, maximum.
Channels
enabled
Certain configurations allow the
user to enable only one channel
of a channel pair. See discussion
and graphs in the final pages of
this datasheet.
Filter tracking/
stepping (requires a
valid speed signal)
Initial condition
Nominal filter set used.
Switch from
nominal to
lower filter set
Current shaft speed ≤ 0.9 x
(Nominal Shaft Speed).
Switch from
lower to
nominal filter
set
Current shaft speed ≥ 0.95 x
(Nominal Shaft Speed).
Switch from
nominal to
higher filter set
Current shaft speed ≥ 1.1 x
(Nominal Shaft Speed).
Switch from
higher to
nominal filter
set
Current shaft speed ≤ 1.05 x
(Nominal Shaft Speed).
Shaft speed
error condition
Nominal filter set used.
Alarms
Alarm setpoints
The user can set Alert levels for
each value measured by the
monitor and Danger setpoints for
any two of the values measured
by the monitor. All alarm setpoints
are set using software