Simon XT
Installation Manual
38
Phone options
Table 13. Phone options
Function
Default
Description
Man phone test
On
Determines whether the user can perform a manual communication test to verify
communication to a central station/voice dial (on), or not (off). If you have all 4 phone #
programmed it should send a test report to all 4 before showing that test is okay.
FTC
On
Determines whether the panel and interior sirens sound trouble beeps if it is unable to
successfully send a report to a central station (on) or not (off).
DTMF dial
On
Determines whether the panel uses DTMF (on) or pulse (off) for dialing programmed
phone numbers.
300 bps enabled On
Determines whether the baud rate used by the panel for central station communication
is 300 bps (on) or 110 bps (off).
Ring hang ring
1
Determines when the panel answers a remote phone access or Enterprise call.
Depending on whether an answering machine exists at the panel location, offsite access
to the panel can be done with a series of phone calls or just one. For offsite access where
an answering machine does not exist, the user or Enterprise operator simply calls the
panel location once and listens for 10 rings. The panel should answer after the tenth ring.
For offsite access where an answering machine exists, the user or Enterprise operator
must perform the following steps:
• Call the panel location.
• Let the phone ring once, then hang up.
• Wait at least 10 seconds but not more than 40, then call the panel location again.
The panel should answer on the first ring.
Ring/hang/ring setting number and sequence of rings after which the panel answers:
1
Ring/hang/ring or ten rings
2
Ring/hang/ring/hang/ring or ten rings
3
Ring/hang/ring/hang/ring/hang/ring or ten rings
4
Ten rings
5
Ring/hang/ring
6
Ring/hang/ring/hang/ring
7
Ring/hang/ring/hang/ring/hang/ring
Off Disabled—no remote (offsite) access
Dial delay
30 seconds
Determines whether the panel delays dialing programmed phone numbers before
sending reports (on).
If Opening (Disarming) Reports is on, the panel
does not delay dialing if the system is disarmed before the delay time expires. The panel
dials immediately for both the alarm and opening report.
Note:
Regardless of this option setting, the panel always dials immediately for fire
alarms, AC power failure and low battery reports.
The delay time can be set from 5 to 254 seconds (15 to 45 if SIA Limits option is on).