Simon XT
Installation Manual
8
15 Instant interior: Interior PIR motion sensors.
Intrusion
F
Y
Y
234
16 Instant interior: Interior doors.
Intrusion
F
Y
Y
34
17 Instant interior: PIR motion sensors and Sound sensors.
Intrusion
F
N
Y
34
18 Instant interior: Cross-zone PIR motion sensors.
Intrusion
F
N
Y
34
19 Delayed interior: Interior doors that initiate a delay before going into alarm.
Intrusion
S
Y
Y
34
20 Delayed interior: PIR motion sensors that initiate a delay before going into
alarm.
Intrusion
S
N
Y
34
21 Local instant interior: 24-hour local alarm zone protecting anything that opens
and closes. No report.
Intrusion
I
Y
Y
1234
22 Local delayed interior: same as group 21, plus activation initiates a delay
before going into alarm. No report.
Intrusion
S
Y
Y
1234
23 Local instant auxiliary: 24-hour local alarm zone protecting anything that
opens and closes. No report.
Emergency
I
Y
Y
01234
24 Local instant auxiliary: 24-hour local alarm zone protecting anything that
opens and closes. Sirens shut off at restoral. No report.
Emergency
I
Y
Y
01234
25 Local special chime: notify the user when a door is opened. Sounds emit from a
local annunciator. One direct bypass and unbypass when no special motion
chime sensors are in the security system. No report.
Three beeps
I
N
Y
01234
26 Fire: 24-hour fire, rate-of-rise heat, and smoke sensors.
Fire
I
Y
Y
01234
27 Lamp control or other customer feature. No report.
Silent
I
Y
Y
01234
28 PIR motion sensor, sound sensor, or pressure mat.
RF thermostat. No report.
Silent
I
N
Y
01234
29 Auxiliary: freeze sensors.
Trouble beeps I
Y
Y
01234
32 PIR motion sensor or sound sensor. No report.
Silent
I
N
N
01234
34 Carbon monoxide alarm.
Emergency
I
Y
Y
01234
35 Entry/exit delay interior PIR motion.
Intrusion
S
N
Y
234
36 Special Intrusion: such as gun cabinets and wall safes. Reports as tamper if
tripped.
Intrusion
I
Y
Y
1234
37 Light switch control: X10 modules turn either on or off when a door is opened.
Silent
I
N
Y
01234
38 Auxiliary: water sensors.
Trouble beeps I
Y
Y
01234
39 Local instant interior: 24-hour local alarm zone protecting anything that opens
and closes. No report.
Intrusion
I
Y
Y
1234
40 Local special chime.
Three beeps
I
Y
Y
01234
Table 4.
Sensor group characteristics (continued)
Ty
pe
Name/application
Siren type
Delay
Res
to
ral
Su
pe
rv
is
or
y
Active In
arming
levels