LOC
PG
DESCRIPTION
DEFAULT
YOUR DATA
1
13
Seg 4 DOUBLE BEEP FUNCTION
3
0 =
All units off
1 =
All lights on
2 =
On
3 =
Off
4 =
Dim
5 =
Bright
6 =
All lights off
Seg 5 TRIPLE BEEP FUNCTION
2
0 =
All units off
1 =
All lights on
2 =
On
3 =
Off
4 =
Dim
5 =
Bright
6 =
All lights off
2
14 READER
OPTIONS
Seg 1 SYSTEM OPTIONS
3, 4
1 =
"On" if enabled for User Card Programming
2 =
"On" if optical tamper enabled
3 =
"On" if buzzer follows keypad buzzing
4 =
"On" if ding-dong chime enabled (Opt 3 & chime must be enabled)
5 =
“On” if an RTE from a scanned card is to be logged as Code Entry
6 =
”On” if an RTE from a zone or the Egress input is to be logged as Code Entry.
7 =
Reserved
8 =
Reserved
Seg 2 SYSTEM OPTIONS
0
1 =
Reserved
2 =
Bypass Hide. When system is armed, all bypassed zone LED’s will be OFF
3 =
Reserved
4 =
Reserved
5 =
Reserved
6 =
Reserved
7 =
Reserved
8 =
Reserved
Seg 3 SCHEDULES FOR RELAY OUTPUT
1, 2, 3, 4, 5, 6, 7, 8
1 =
"On" if relay output follows Schedule 1.
2 =
"On" if relay output follows Schedule 2.
3 =
"On" if relay output follows Schedule 3.
4 =
"On" if relay output follows Schedule 4.
5 =
"On" if relay output follows Schedule 5.
6 =
"On" if relay output follows Schedule 6.
7 =
"On" if relay output follows Schedule 7.
8 =
"On" if relay output follows Schedule 8.
NX-1750 Installation manual
Page 20
18/02/05