Simon Security System
8
Alarm Sirens and Lamp Modules
Exterior and interior sirens make 3 different alarm sounds on the premises, each indicat-
ing a different type of alarm. Sirens are programmed by the installer to time-out and
stop sounding after a specified time.
Use the following table to understand the siren sounds used by the security system.
Temporal 3 refers to a continuous pattern of 3 siren pulses then off for 2 seconds, 3 siren
pulses then off for 2 second.
Status Beeps
Activity
Beep Response
ARM Doors & Windows
Exit delay
and
Entry delay
beeps sound 2 times
every 5 seconds and 2 times per second during the
last 10 seconds (if Silent Exit is used, the Exit delay
beeps will only sound twice when you arm and
twice when the Exit delay expires)
ARM Motion Sensors
Exit delay
and
Entry delay
beeps sound 3 times
every 5 seconds and 3 times per second during the
last 10 seconds (if Silent Exit is used, the Exit delay
beeps will only sound 3 times when you arm and 3
times when the Exit delay expires)
ARM Doors/Windows &
Motion Sensors
Exit delay
and
Entry delay
beeps sound 4 times
every 5 seconds and 4 times per second during the
last 10 seconds (if Silent Exit is used, the Exit delay
beeps will only sound 4 times when you arm and 4
times when the Exit delay expires)
DISARM
1 beep
CHIME DOORS
2 beeps (feature must be programmed by installer)
CHIME SPECIAL MOTION
3 beeps (feature must be programmed by installer)
Trouble Beeps
6 beeps every minute. Press the SYSTEM STATUS
button to stop beeps for 4 hours
No Activity Beeps
20 beeps every minute for 5 minutes (feature must be
programmed by the installer)
Alarm Sirens and Lamp Modules
Alarm Type
Interior Siren Sound
Exterior Siren Sound
Lights
Fire
Temporal 3
Temporal 3
Turn on
Intrusion On
steady
On
steady
Flash
Emergency
Fast on-off
________
Turn on