0150-0242C
69
Kalatel DVMRe
Matrix
Other display options include:
•
A full screen display of a single camera in alarm, with a sequenced full screen display for
additional cameras in alarm. This option is selectable in the menu system (see Full Screen Alarm
in section 3.11).
•
Freeze camera display at the time the alarm was received.
Monitor-B Display During Alarm
Single Alarm:
Unit switches to a full screen display of the camera in alarm.
Additional Alarms:
Unit switches to a sequenced display of all cameras in alarm.
Full-Screen Displays on Monitors B through E During Alarms
Salvo Switching Disabled
During alarms, the monitor (B through E) designated as Aux Monitor in the menu switches to a
full-screen display of the camera in alarm. The other monitors continue to display their current
cameras and not change due to alarm.
If multiple alarms are active, the designated Aux Monitor sequences among the alarm cameras at a
fixed 1-second dwell, which is not programmable. Monitors B through E cannot freeze images on
alarm.
Salvo Switching Enabled
During alarms, the Aux Monitor setting has no effect. Monitors B through E switches to a full-screen
display of the cameras programmed as the Input Group in the Alarm Action Setup menu.
For example, if input alarm 01 is activated, Group 01 cameras display on Monitors B through E.
If multiple alarms are active, Monitors B through E sequence between the alarm camera Groups at a
fixed 1-second dwell. This dwell is not programmable. Monitors B through E cannot freeze images on
alarm.
The Monitors B through E screens do not revert to original fixed displays after the alarm
is cleared. They continue to display the last alarm camera. But, if sequencing was
active on Monitors B through E before the alarm, then Monitors B through E continue to
sequence after the alarm is cleared.
If the user changes the screen format while an alarm is active, then the unit continues to display the
selection after the alarm clears. It does not revert to the pre-alarm screen display.
Full-Screen Alarm
If the programmer does not install Monitors B through E and relies solely on Monitor A for all system
information, a full-screen alarm display on Monitor A may be preferred to the custom multiscreen
displays.
In this case, the programmer can select a menu option in the
Alarms
menu that makes Monitor A:
•
Switch to a full-screen display of the camera in alarm.
•
Sequence full-screen between multiple alarms (as Monitors B through E normally do).
NOTE
Содержание Kalatel DVMRe Matrix
Страница 92: ...0150 0242C ...