0150-0242C
60
Kalatel DVMRe
Matrix
Port 2
Use this menu to configure the baud rate for Port 2. Rotate the
Jog to select a baud rate from the menu.
Save changes and exit the menu:
Press the
Enter
button.
Exit the menu without making changes:
Press the
Menu
button.
The RS232 port 2 is used for Event Generation and ASCII Text
Insertion. See Section 7 for the RS232 Protocol required to perform
these functions.
q
Main Menu
→
Communications
→
RS485
Connect several units to a single keyboard, or vice-versa. Up to
32 units (any combination of multiplexers and keyboards) can be
networked together. Use this menu to specify the units unique network address.
Save changes and exit the menu:
Press the
Enter
button.
Exit the menu without making changes:
Press the
Menu
button.
q
Main Menu
→
Communications
→
Ethernet Settings
An ethernet connection can be used to connect to the unit from a
PC for the viewing of live or recorded images. Use this menu to
configure the Ethernet communications settings. Select from the
following:
Ethernet:
Select Enable or Disable.
Hostname:
Not selectable. Pulled from the systems serial number.
DHCP:
Select Enable or Disable. Enables dynamic IP addressing.
When DHCP is enabled, the IP address, Subnet Mask, Gateway,
and Server fields are dynamically addressed.
Name Service:
Select from Disable or WINS. Enabling WINS
registers the hostname and IP address within the current Network.
This ensures that you can connect to the Matrix by hostname
within the network.
IP Address / Subnet Mask / Gateway:
Consult with a qualified
Network Administrator or an MIS professional to configure these
settings if DHCP is not enabled.
Primary Name Server / Backup Name Server:
The IP addresses of the Primary and Backup Name
Servers. Not required if DHCP is enabled.
Print Server:
Enter the Print Servers IP address to enable the Print Image operation (Function and
Zoom).
TCP MTU Size:
Select from Standard, 1400, and 1200. The MTU describes the maximum possible TCP
packet size. Standard (1500) is optimal for most ethernet network environments.
Network Address
01
1200 Baud
2400 Baud
4800 Baud
19200 Baud
38400 Baud
57600 Baud
9600 Baud
Ethernet Settings
[CANCEL] [OK]
Ethernet :
Hostname : D406T2250419
DHCP : Disable
Name Service : Disable
IP Address
Subnet Mask : 255.255.254. 0
Gateway
Primary Name Server : 3. 18.173. 12
Backup Name Server : 3. 18.173. 13
Print Server
Enable
: 3. 18.173. 60
: 3. 18.172. 1
: 3. 18.173. 11
TCP MTU Size : Standard