24
Programming the Panel
Reporting Menu
The REPORTING menu lets you set up which system
events (global or partition) are reported to the central moni-
toring station.
The following describes how to program the reporting set-
tings that appear under GLOBAL.
Keychain TP Arm (Touchpad Options—Partition 1)
(0403)
(Default = off) This setting determines how the keychain
touchpad arms the system. When set to ON, pressing the
lock button arms the system directly to AWAY with NO
DELAY. When set to OFF, pressing the lock key
increments the arming level from OFF to STAY and from
STAY to AWAY.
To change the Keychain Touchpad Arming set-
ting:
With the display showing KEYCHAIN TOUCHPAD
ARM OFF/ON (current setting), press
1
(off) or
2
(on).
The display flashes the entered setting. Press
ƒ
and
the display shows the new setting.
Star Is No Delay (Touchpad Options—Partition 1)
(0404)
(Default = off) This setting determines whether the
keychain touchpad star button controls an onboard or
SnapCard output (off) or the NO DELAY feature (on).
To change the Keychain Star Is No Delay set-
ting:
With the display showing STAR IS NO DELAY OFF/
ON (current setting), press
1
(off) or
2
(on).
The display flashes the entered setting. Press
ƒ
and
the display shows the new setting.
24-Hour Tamper
(Reporting—Global)
(05000)
(Default = off) When this feature is turned on, the panel
sounds sirens and reports a tamper alarm when wireless
sensor tamper switches are activated (even when the system
is disarmed).
To turn 24-Hour Tamper off or on:
With the display showing 24-HOUR TAMPER OFF/
ON (current setting), press
1
(off) or
2
(on).
The display flashes the entered setting. Press
ƒ
and
the display shows the new setting.
Buffer Control
(Reporting—Global)
(05001)
(Default = off) When this setting is on, only arming level
changes are logged into the buffer (memory) of the panel.
When this setting is off, all system events are logged in the
buffer.
To turn Buffer Control off or on:
With the display showing BUFFER CONTROL OFF/
ON (current setting), press
1
(off) or
2
(on).
The display flashes the entered setting. Press
ƒ
and
the display shows the new setting.
Back In Service
(Reporting—Global)
(05002)
(Default = on) When this feature is turned on, the panel
reports to the central station when AC and backup battery
power are restored (after an extended power outage).
To turn Back In Service reports off or on:
With the display showing BACK IN SERVICE OFF/
ON (current setting), press
1
(off) or
2
(on). The
display flashes the entered setting. Press
ƒ
and the
display shows the new setting.
Bypass Reports
(Reporting—Global)
(05003)
(Default = off) When this feature is turned on, the panel
reports to the central station (or a pager) whenever sensors
or zones are bypassed.
To turn Bypass Reports off or on:
With the display showing BYPASS REPORTS OFF/ON
(current setting), press
1
(off) or
2
(on). The display
flashes the entered setting. Press
ƒ
and the display
shows the new setting.
Low CPU Battery
(Reporting—Global)
(05004)
(Default = on) When this setting is on, the panel reports a
low panel battery to the central station (or pager) before
shutting down.
Ìi
For UL listed systems, Low CPU Battery must be
set to “on.”
To turn Low CPU Battery reports off or on:
With the display showing LOW CPU BATTERY OFF/
ON (current setting), press
1
(off) or
2
(on). The
display flashes the entered setting. Press
ƒ
and the
display shows the new setting.
Содержание CONCORD Express
Страница 49: ...50 Troubleshooting ...