![GDZX ZXR-40A Скачать руководство пользователя страница 7](http://html.mh-extra.com/html/gdzx/zxr-40a/zxr-40a_instructions-manual_571839007.webp)
ZXR-40A
- 6 -
After the winding under test is wired and the suitable measuring current is selected, press the
“Measure” key-press to allow the tester to enter into its measuring state and to start to supply
power to the winding, and then it enters into the interface as follows:
2 0 0 7 . 0 1 . 0 1
Tap
R
0. 0 A
Store
The battery is charging, please wait a moment
!
Current tap:
01
Re-test
Exit
1 4 : 0 2 : 5 1
At this time, the current of the winding starts to increase. If the charging progress strip and the
current display value stand still for a long time, it indicates that the value of the resistance value
to be measured is probably beyond the measuring scope of the current, so it is not able to reach
its set value. At this time, press “Exit” key-press to return and re-select the current and retry.
When the set value is reached, it becomes constant. Then, enter into the next interface.