![GDZX ZXR-40A Скачать руководство пользователя страница 5](http://html.mh-extra.com/html/gdzx/zxr-40a/zxr-40a_instructions-manual_571839005.webp)
ZXR-40A
- 4 -
①
Ia
Ib
Ic: The dc current output. In case of single phase or two-phase measurement, Ia
and Ib are current output.
②
Ua Ub Uc Uo: The input of measuring voltage. In case of single-phase measurement,
Ua and Ub are voltage input. In case of two-phase measurement, Ua and Ub are the voltage
input of the first channel; Uc and Uo are the input of the second channel.
3
Panel printer: Prints the output measurement results.
4
LCD: displays the measurement results and operation prompting information, with the
function definition of the five multi-function key-presses under the current state given in
the key definition zone on the right, as shown in the figure below :
2 0 0 7 . 0 1 . 0 1
Set
Measurement mode: three phase
Measuring current: 20 A
View
W
iri
ng
D
ia
gr
am
Mode
Current
Measure
1 4 : 0 2 : 5 1
5
: Contrast regulation of LCD
6
Power socket: the power input of the complete unit, with built-in fuse tube. The fuse
tube is 10A/250V.
7
Earthing pole: The earthing pole on the enclosure of the complete unit. Make sure that it is
reliably grounded during measurement.
4. Testing and Operating Method
1
Connect with the power source and earth wire, switch on the power supply to enter into
the initial interface, as shown in the figure below: