5. INSTALLATION OF ENTERPRISE STORAGE/ ENTERPRISE STORAGE PLUS
INSTALLATION MANUAL FOR LPU-1000 LED PLAYER UNIT
-55-
26 Feb 2018
RAID LED
Please see the table below for an explanation of RAID LED indicator:
Red
Buzzer
RAID
LED
Flashing
Degrade/Broken
ON
Off
Normal
OFF
5.8.2. Warning Buzzer
Buzzer mute switch is located to the right of the RAID LED. Use a pen or similar shaped object to turn the buzzer
on or off.
WARNING:
This is not a reset switch for the buzzer. Once the button is toggled
to the “off” position, the buzzer will remain
silent if any other hard disk fails. Please remember to toggle the switch on after replacing any failed hard disks.
5.8.3. Hard Drive Failure
When a hard disk is showing an error, the hard disk must be removed.
When a replacement hard disk is inserted into the bay, it will be added into the RAID array immediately; the
RAID array will start the rebuilding process automatically.
Note:
The hard disk must be a fresh drive. DO NOT reuse a hard disk from another Enterprise Storage/ Enterprise Storage
Plus.