EN
5/24
ment.
2.
Close cylinder valve.
3.
Open all downstream valves to release pressure in system.
4.
Unscrew pressure adjusting control knob to close regulator valve.
5.
Close all downstream valves.
lmportant - outlet connection
The outlet of this regulator i s a “PARKER CP1 SINGLE FERRULE TUBE
FITTING” suitable for 6,3 mm 0/D tube only. Another outlet could be re-
frigerant W 11 x 1 ,25. The outlet on the standard industrial S 400 is G
3/8 male cone.
Use only tube suitable for gas and pressure service. {200 or 300 bar) The
300 bar tube i s necessary to use for regulators with the in let pressure
300 bar and without relief valve. {i. c. S2500 and JC 600- 300 bar).
Use only nut and ferrule supplied to secure tube into regulator outlet.
Assembly instruction
1.
Ensure olive and nut are correctly assembled on the regulators outlet
nipple.
2.
Ensure tube end is cut clean and square.
3.
lnsert the tube until it bottoms in the fitting body.
4.
Tighten the nut finger tight.
5.
Further tighten the nut to 1.1/4 turns using suitable spanner.
6.
Pressurise assembly and leak test.
WARRANTY
The product warranty period is 24 months from the date of sale.
The customer has to bring a proof of purchase.
SERVICE, REPAIRS
Repairs within and after finishing warranty period are provided by:
GCE, s. r. o., 583 81 Chotěboř.
Distribution :
GCE, s. r. o.
583 81 CHOTĚBOŘ
3.