5.3 Set Temperature
The Falcon 60 H has upper roller heating
capabilities which enables the machine to run Lo-Melt
film. You can set a desired temperature from 32
O
F
( 0
O
C ) up to 200
O
F ( 93
O
C ).
When power to the temperature controller unit is
supplied, the display indicates the current temperature of
the upper roller.
CAL 3200
(72 is an example of room temperature )
To display the current set point value of the
temperature controller unit, press and hold the star key
located just to the left just below the temperature display.
When the star key is released, the temperature display
reverts to the current temperature of the upper roller.
CAL 3
Increase set point
a) Press and hold
✽
key while pressing
▲
key to
increase the set point temperature. Single presses
of the
▲
key increases the set point by increments
of one while holding the key down will increase
by increments of ones then tens.
CAL 3
0
b) Release the
✽
key and
▲
key once desired set
point has been obtained.
Decrease set point
a) Press and hold
✽
key while pressing
▼
key to
decrease the set point temperature. The same
increments apply.
CAL 3
b) Release the
✽
key and
▼
key once desired set
point has been obtained.