TROUBLE SHOOTING GUIDE
SYMPTOM POSSIBLE
CAUSE
CORRECTIVE
ACTION
The control panel display does not
illuminate when POWER ON/OFF
is in the ON, marked “I”, position
Laminator not connected to
electrical supply
Insert attachment plug into
receptacle
Blown out fuse.
Check fuses.
Rollers do not turn when Load or
Run is pressed.
Safety latch not engaged
Check all Safety latches.
Pull E-Stop button
Pull out on the E-STOP push button.
Laminated items exhibit curling.
Too much Brake on Film
Adjust tension per section FILM
TENSION.
Decurling bar not set correctly
Adjust Decurling bar to increase or
decrease curl.
Wet Media
Turn on Cooling Fans or let Media
cure.
Adhesive deposited on heat rollers.
Top film exceeds image size.
Re-orientate film or images, or slit
film.
Laminate improperly loaded.
Adhesive (matte) side of laminate
film may be against the heat rollers.
Unweb and reload the film properly.
Unsatisfactory adhesion of laminate.
Speed setting too fast for type of
material being laminated
Lower speed setting.
Insufficient heat
Wait for “READY” indicator to
appear in the control panel display.
Laminate improperly loaded
Adhesive side of film must be facing
away from the heat rollers.
Heat rollers require cleaning.
Bottom roll of film not threaded
behind the idle bar.
Laminated item unsuitable for
adhesion.
Clean heat rollers per procedure in
section CARING FOR THE GBC
620os LAMINATOR. Item may be
dirty or may have non porous
surface that is extremely difficult to
laminate.
Insufficient PSI
Increase PSI