BATTERY CHARGING

The battery should be charged according to 

the following steps:

Take the supplied charging cable and connect its 

magnetic connector to the counterpart on the back 

of the control box.

Plug the other end of the cable into the power 

adapter supplied or any standard powered USB-A 

port.

 The LED on the left side of the front panel (near the 

ON/OFF  button)  will  flash  red  indicating  the 

charging process. When the battery is fully charged, 

the red light will turn blue.

Wait until the charging is complete and disconnect 

the cable in the reverse order: the cable end from 

the  power  adapter  first  and  then  the  magnetic 

connector from the control box.

The Gauss MiL is powered by a built-in lithium-ion battery. The included USB charging cable 

with a magnetic connector is used to charge the battery.

Important! Strictly observe the 
procedure for connecting the 

charging cable indicated in this 
manual. Keep the magnetic cable 
connector away from metal particles 

to avoid short 
circuiting and 
breakdown of 
the power 
adapter or 
other device 

the charging 
cable is 
plugged into.

Important! To avoid battery 

damage, never charge a 

battery in an area with an ambient 

temperature of less than 5ºC. Always 

allow the control box to first warm up 

to room temperature for a few hours, in 

order to then charge the battery under 

optimum condition.

Battery maintenance

Lithium-ion battery may degrade if 

they aren’t in use for long periods of 

time. Fully charge the battery regularly, 

at least once every 2-3 months. 

However, be aware that the lithium-ion 

battery capacity decreases gradually 

with time, even under normal usage 

conditions. In view of this, the battery 

needs to be replaced every few years. 

Replacement batteries can be supplied 

and installed by an authorized service 

center.

The charging time for a completely 
discharged battery is estimated to be about 

5 hours if the charging adapter provides a power 
output of 5V and 1A. Less power from the power 
source may extend the charging time. If the 
detector is turned on while charging, the charge 
time will be longer.

To charge the Gauss MiL, the use of any quick charge AC power adapters is prohibited!

It may cause damage or destroy the battery. 

Use the power adapter supplied in the package.

1

2

3

4

Содержание MIL MD

Страница 1: ...OPERATING MANUAL Gauss MD PROFESSIONAL METAL DETECTOR with Gauss MiL rmware...

Страница 2: ...tenance Safety 17 Error Messages 18 Technical Specifications TABLE OF CONTENTS 3 4 5 5 6 7 9 11 12 12 12 13 14 15 15 16 16 17 THE USE OF THE METAL DETECTOR WHILE CONDUCTING MINE CLEARANCE ACTIVITIES i...

Страница 3: ...l attachment bolt 2 pcs 10 Tiger search coil coil cover connector protection cap 11 Tiger search coil coil cover connector protection cap 12 MarsMD Pointer 13 Carry bag 1 The Gauss MiL can be addition...

Страница 4: ...oosening direction Tightening direction Coil attachment bolt Rubber washers 4 Wrap the coil cable around the lower shaft in such a manner that the first loop close to the coil goes over the top of the...

Страница 5: ...gs and modes features will allow you to use your metal detector in the most effective and efficient way possible while searching 1 Assemble the device according to the instructions given on page 4 see...

Страница 6: ...target depending on its characteristics Displays the value of the GAIN setting which stands for the detector sensitivity Battery Status Indicator Indicates the current charge level of the battery Sta...

Страница 7: ...atest settings changes are saved in non volatile memory of the device before it turns o FREQUENCY FREQ LF1 LF5 is the detector s operating frequency with the value within the 16 kHz 200 Hz range The L...

Страница 8: ...rian and military demining iL is a special mode designed to detect metal containing explosives In this mode the metal detector has one tone audio indication without determining the type of metal ferro...

Страница 9: ...do the opposite action decrease the value using Press the buttons several more times until you get such GEB value when the sounds become as quiet as possible or completely silent while the coil is swu...

Страница 10: ...lue provides the current information about the ground you are searching on The range of 6 20 is common to poorly mineralized sandy soils The range of 20 45 is typical for dry clay loams and black soil...

Страница 11: ...target which additionally helps to identify its position and estimate the burial depth To determine the exact position of a target 1 After the approximate target location is detected move the coil aw...

Страница 12: ...N MODE Target ID is the number produced by the device while identifying a buried object based on the electromagnetic properties of metals and physical dimensions of the item found Ferrous targets most...

Страница 13: ...wer adapter or other device the charging cable is plugged into Important To avoid battery damage never charge a battery in an area with an ambient temperature of less than 5 C Always allow the control...

Страница 14: ...Li Ion battery and a built in charge controller To charge the battery you need to plug one end of the USB mini USB cable supplied into the mini USB output on the module and the other end into the USB...

Страница 15: ...the contacts are clean 2 Ensure the nut on the coil connector is firmly tightened 3 Move away from the source of interference 4 Try switching to another operating frequency 5 Reduce the detector s se...

Страница 16: ...treated with due care Use a screen protector to keep it pristine Do not expose the detector to extreme temperatures Operating temperature range 20 C to 45 C GENERAL CARE Do not use solvents to clean...

Страница 17: ...tness levels internal Li ion battery up to 24 hours but not less than 15 hours Detecting Range Operating Frequency Indication Ground Balance Built in Transmitter LCD Backlight Power Supply Operating T...

Страница 18: ...gaussmil com ___________________ E mail mail marsmd com...

Отзывы: