This is a legal agreement between you, the end user, and Gaumard® scientiic company, inc. (“Gaumard”). This software is protected by copyright 
laws and remains the sole property of Gaumard. By installing the UNI™ (the “software”) media, you agree to be bound by the terms of this agreement. 
If you do not agree to the terms of this agreement, promptly return the uninstalled media and accompanying items to Gaumard at the address 
indicated below.

1. Grant of License:

 Gaumard hereby grants to you (an individual or institution) the right to install and activate the software on one computer for use 

with one interactive patient simulator system. The software may also be installed on any number of other computers at the same institution so that 
students may access the learning resources. One copy of the software may be made for backup purposes. You may not network this software, or 
allow multiple users unless you purchased a multi-user workstation license. Sharing this software with other individuals or allowing other individuals 
to view the contents of this software is in violation of this license.

2. Copyright:

 The software is owned by Gaumard and protected by United States copyright laws and international treaty provisions. Therefore, you 

must treat this software like any other copyrighted material. You may not make this software or copies thereof available in any manner or form or 
use, copy or transfer the software, in whole or in part, except as provided herein.

3. Other Restrictions:

 You may not rent or lease this software to any other party. You may not alter, merge, modify, adapt, reverse engineer, decompile 

or disassemble the software, or disclose the contents of this software to any other party.

4. Electronic Transmission of Software:

 If you received the software by electronic transmission or by internet delivery, by installation of the software, 

you acknowledge that you have read and understand this license agreement and agree to be bound by its terms and conditions.

5. Term of Agreement:

 The term of this agreement and the license granted to you pursuant hereto shall commence upon installation of this software. 

This agreement and the license granted herein may otherwise be terminated by Gaumard in the event that you are in breach of any provision of this 
agreement. In the event of termination, you agree to immediately return this software, accompanying items, and any copies thereof to Gaumard.

6. Limited Warranty:

(A) The cd-rom media (the “media”) which contains this software is warranted, for a period of 30 days from the date of purchase, to be free from 
defects in material and workmanship. Electronic transmission is warranted to be free from defects at the moment of transmission. Your sole and 
exclusive remedy, and Gaumard’s sole liability, is to replace the defective media or to repeat the electronic transmission provided that you notify 
Gaumard in writing of such defect or defective transmission and return the defective media, if any, during the 30-day warranty period.

(B) Except and to the extent expressly provided in paragraph (a), the software and accompanying written materials are provided on an “as is” basis, 
without any warranties of any kind, including, but not limited to, any implied warranties of merchantability or itness for any particular purpose. No oral 
or written information or advice given by Gaumard, its dealers, distributors, agents or employees shall create a warranty or in any way increase the 
scope of this warranty, and you may not rely on any such information or advice. Gaumard does not warrant, guarantee, or make any representations 
regarding the use or the results of use, of the software or written materials in terms of correctness, accuracy, reliability, currentness, or otherwise, and 
the entire risk as to the results and performance of the software is assumed by you. If the software or written materials are defective, you and not 
Gaumard or its dealers, distributors, agents, or employees, assume the entire cost of all necessary servicing, repair or correction other than expressly 
described above.

(C) Neither Gaumard nor anyone else who has been involved in the creation, production or delivery of this product shall be liable for any direct, 
indirect, consequential or incidental damages (including damages for loss of business proits, business interruption, loss of business information, 
and the like) arising out of the use or inability to use such product or related to this agreement even if Gaumard has been advised of the possibility 
of such damages. Gaumard shall not be liable to you for any indirect, special, incidental, or consequential damages or lost proits arising out of or 
related to this agreement or your use of the software and/or the related documentation, even if Gaumard has been advised of the possibility of such 
damages. In no event shall Gaumard’s liability here under, if any, exceed the purchase price paid by you for the software.

All rights not expressly granted in this license agreement are reserved by Gaumard.

ACKNOWLEDGMENT

By installation of this software, you acknowledge that you have read and understand the foregoing and that you agree to be bound by its terms 
and conditions. You also agree that this agreement is the complete and exclusive statement of agreement between the parties and supersedes all 
proposed or prior agreements, oral or written, and any other communications between the parties relating to the license described herein.

End User License Agreement

Содержание PREMIE Blue S108.250

Страница 1: ...ntiic All Rights Reserved www gaumard com PREMIE Blue S108 250 is an interactive educational system developed to assist a certiied instructor It is not a substitute for a comprehensive understanding o...

Страница 2: ......

Страница 3: ...onditions 2 Storage Conditions 2 Procedures 2 Cleaning 2 2 Getting Started 3 2 1 Overview 3 Airway 3 Appearance 3 Artiicial Respiration 3 Circulation 3 Simulator 3 Venous Access 4 2 2 Terminology 4 Fa...

Страница 4: ...5 Umbilical Catheterization 17 Directions for Use 17 Heelstick 18 5 Using OMNI 2 19 5 1 Main Screen 19 Changing a Vital Sign 19 5 2 Hypoxia 20 5 3 CPR 21 Feedback Graphics 21 Actions 22 Calibration 2...

Страница 5: ...rkmanship Electronic transmission is warranted to be free from defects at the moment of transmission Your sole and exclusive remedy and Gaumard s sole liability is to replace the defective media or to...

Страница 6: ...PREMIE Blue S108 250 User Manual 6 Introduction...

Страница 7: ...arts are available from Gaumard Scientiic or from your Distributor IV Arm Only use Gaumard s provided simulated blood Any other simulated blood containing sugar or any additive may cause blockage and...

Страница 8: ...ocedures Do not attempt to intubate without lubricating the airway adjunct with mineral oil lubricant Failure to lubricate the device will make intubation very diicult and is likely to result in damag...

Страница 9: ...aneuver Appearance Color responds to hypoxic events and interventions healthy mild cyanosis severe cyanosis Articulated head neck jaw arms and legs Artiicial Respiration Bilateral lung expansion with...

Страница 10: ...Venous Access Patent umbilicus Intraosseous access at tibia IV training arm 2 2 Terminology Facilitator The person conducting the simulation an instructor or lab staf member Provider A person partici...

Страница 11: ...ted on Premie Blue s left side and then connect the power supply to the wall outlet Always operate Premie Blue with the power supply connected OMNI 2 Connection OMNI 2 controls Premie Blue s responses...

Страница 12: ...ecting the simulator features 4 Follow the on screen tutorial for a brief overview of the features of OMNI 2 5 Move onto the next steps in the Tutorial by selecting GOT IT 6 Exit the Tutorial at any t...

Страница 13: ...torial OMNI 2 will automatically proceed to the Favorites page and establish a connection to Premie Blue WARNING Do not connect Premie Blue or OMNI 2 to a computer LAN network or unathorized diagnosti...

Страница 14: ...t sized mask having a thick seal Intubation Premie Blue airway can be intubated orally and nasally using a 2 5 mm ID Endotracheal tube An LMA can be used to ventilate Premie Blue orally WARNING Nasoga...

Страница 15: ...as IV access in the lower right arm that can be used for bolus or intravenous infusion as well as for draining luids The lower arm contains a vein groove which is itted with a soft tube closely simula...

Страница 16: ...ustable clamp Drainage container not included in kit 2 Fill the dispensing syringe with luid 3 Connect the syringe to the illing tube 4 Allow luid to low through the system and into the drainage conta...

Страница 17: ...lature system Use a 25 27 gauge needle set IV Maintenance Replacing the arm skin 1 Gently pull the IV arm skin 2 Add a small amount of lubri cant to the arm 3 Slide the replacement skin onto the arm R...

Страница 18: ...black electrical con nector is visible 4 Unfasten the connector by pressing on the clip 5 The male electrical connector resides in the upper arm 6 Locate the replacement item 7 Take the female connec...

Страница 19: ...simulator 11 Place the screw into the other side of the elbow joint and fasten until the connection is secure 4 3 Intraosseous Access Setting up an intraosseous access line is an invasive procedure th...

Страница 20: ...ure in the bone using inlet and drain valves Directions for Use Tube 1 illing Tube 2 drainage tube 1 Place the end of tube 2 into a drainage container and open the adjustable clamp 2 Fill the dispensi...

Страница 21: ...sh remaining luid out the system If blood mix is used lush the system with 2 3 syringes full of clean water Holes in the bone s that are made by the IO needle can be sealed with Superglue Replacing th...

Страница 22: ...ue Features 4 Pull out the tibia bone out of the leg 5 Insert the new tibia The illing and drainage tubes are irst followed by the bone 6 Re attach tibia cover 7 Connect the syringe connector to the i...

Страница 23: ...determine whether they meet or exceed conventional neonatal CPR standards If acceptable the OMNI 2 tablet causes the skin to turn to a more healthy color if inadequate or non existent OMNI 2 causes t...

Страница 24: ...uid to low through the system and into the drainage container 6 Once the luid is seen draining close the adjustable clamp For catheterization use an umbilical catheter WARNING Lubricate the distal tip...

Страница 25: ...ing a Vital Sign Vital signs can be quickly changed from the Favorites Page or from the Vitals page Follow the steps below to change one of the parameters 1 Tap on a vital sign 2 Adjust the vital sign...

Страница 26: ...stan dards To start a hypoxia session follow the steps below 1 Select the initial state of the simulator Choose from none peripheral or central cyano sis Premie Blue will display full cyanosis or par...

Страница 27: ...R by monitoring cadence and depth of cardiac compressions and airway ventilations in real time WARNING Do not perform mouth to mouth ventilation since the simulator airway can be diicult to clean afte...

Страница 28: ...e make sure to calibrate the com pressions Perform the following to calibrate the compressions 1 Tap the gear on the up per right of the screen 2 Select Calibration Buttons Function Begin and end a CP...

Страница 29: ...8 250 User Manual Using OMNI 2 23 3 Select Compression once the calibration window appears 4 Adjust the Target compression depth with the and tap START 5 Follow the prompts to calibrate the target com...

Страница 30: ...E Blue S108 250 User Manual 24 Using OMNI 2 6 Select SAVE to apply the changes 7 Tap Start to begin a CPR session For more information about the CPR monitoring and reporting refer to the OMNI 2 User G...

Страница 31: ...rchase with OMNI 2 Follow the steps below in order to activate this feature 1 Connect the provided router to the wall 2 Tap the gear on the top right of the screen 3 Select WIFI Connection Setup 4 Con...

Страница 32: ...itor 8 Follow steps 9 10 if the activation code was not inputted 9 Verify that the serial num ber corresponds to the manikin 10 Input a valid activation code The activation code is case sensitive Note...

Страница 33: ...itors software 15 Tap the V on the top left and then select Comm Setup 16 Verify that the IP address in the Wireless Communication Setup matches the Omni IP and Omni Port noted before 17 Select Connec...

Страница 34: ...nd re placement parts and their prices Item Type Code Artiicial Blood Concentrate Consumable S108 812 Lubricant Consumable S108 974 Arm Skin Replacement S108 813 L M D Lower Intravaneous Right Trainin...

Страница 35: ...the right and click Forget the network Manikin is not paired Disconnect the simulator from the power supply turn of bluetooth on OMNI 2 tablet Plug the simulator back in and turn on bluetooth Power s...

Страница 36: ...subsequent purchasers or users of the product acquire the product as is and this limited warranty does not apply This limited warranty applies only to the products manufactured and produced by Gaumar...

Страница 37: ...e Seatbelt Susie Krash Kids Premie UNI Omni Omni 2 SmartSkin are trademarks of Gaumard Scientiic Company Always dispose of this product and its components in compliance with local laws and regulations...

Отзывы: