background image

Instructions for SL500DC/SL800DC

www.gatexpertstore.com

1

Then the gate will move

in the set direction.

Default Setting Instruction

The gate opener will open the gate to the right-hand side as its default setting. By default, the
opener mounts on the right-hand side. (Figure 1)

Gate in closed position

Gate in open position

Figure 1

Before installation:

Test the gate opener by plugging it into a power source and pressing the

remote. Press the opening button, the output gear rotates, then press the stop button, the output
gear stops rotating. Finally, press the closing button, the output gear rotates to the opposite
direction. This will give you an understanding of the way in which the opener will move the gate.

Figure 2

Note: Ensure that the gate opener is unplugged before proceeding with installation. Please keep

fingers away from the motor output gear whilst it is turning.

If your gate needs to open from the other direction (to the left, refer to figure 3), your opener needs
to be mounted on the left-hand side as shown.

Figure 3

Any works done to the gate opener must be completed whilst the power is off, and the opener is

unplugged.

Press the first/top button

on the remote.

Rotating output gear will

drive the gate frame.

Содержание SL500DC

Страница 1: ...Sliding Gate Opener User Manual SL500DC SL800DC Website www gatexpertstore com E mail sales gatexpertstore com...

Страница 2: ...fully incorrect installation could affect gate operation When mounting and positioning this product please ensure the power cable is unplugged The motor cover will need to be removed to mount the moto...

Страница 3: ...or replace for free 4 The malfunction and damages caused by incorrect use or man fault is not covered by this warranty CONTACT US E mail sales gatexpertstore com Please fill in the order information i...

Страница 4: ...n 12 Step 9 Testing Travel and Limit Stop Position 13 Programming and Wiring 14 Terminal Instructions 15 Wiring to the Terminal 15 Connecting Infrared Photocells 17 Operation Interface Instruction 18...

Страница 5: ...rt up Delay Setting L3 37 Opening Direction Setting L4 39 Alarm Lamp Setting L5 40 Other Menu Setting 41 Emergency Stop Distance Setting L1 42 Buzzer Setting L2 43 Battery Level Checking 45 Restore Fa...

Страница 6: ...output gear stops rotating Finally press the closing button the output gear rotates to the opposite direction This will give you an understanding of the way in which the opener will move the gate Fig...

Страница 7: ...ent injury to person or damage to property Instruct all users about the control systems provided and the manual opening operation in case of emergency Ensure that the power cable is connected to a RCD...

Страница 8: ...Release Keys 2 3 Remote Controls 2 4 Accessories Box 1 4 1 Limit Switch Stop Bracket 2 Magnet Limit Switch Stop 2 Magnet Limit Switch Stop Mounting Screws M6X18 2 Nuts M8 4 Flat Washers 8 2 Spring Wa...

Страница 9: ...ows secure access through the gate used with a user set code Wired control Allow users to control the opening and closing of the gate through an external push button Alarm lamp Alerts people near the...

Страница 10: ...s a safety feature to ensure safe operation The opener must be fitted within private property never externally to a property s boundary Any works done to the gate opener must be completed whilst the p...

Страница 11: ...formance of the automatic gate opener The gate should slide smoothly by hand before attempting to install the gate opener Figure 5 Step 2 Checking Manual Release Insert the key and open the manual rel...

Страница 12: ...rface is level and parallel to the driveway Mounting Plate Dimensions Figure 8 Step 5 Fitting Mounting Plate and Motor Without Mounting Plate Pre embed the anchor bolts according to holes in motor bas...

Страница 13: ...ht of the motor Figure 10 With Mounting Plate Pre embed the anchor bolts as per 10 holes in Figure 8 before concreting after concrete hardening place the mounting plate fit and tighten anchor bolts as...

Страница 14: ...he output gear has a minimum clearance of 1 2mm along the entire length of gear rack fitted to the gate as per Figure 14 Ensure output gear and gear rack are correctly aligned Under no circumstances s...

Страница 15: ...n your gate opener kit are two magnet limit switch stops with two different polarities stop in black color N stop in blue color S These two stops must be fitted to the gear racks on your gate to ensur...

Страница 16: ...the control board will record the gate running direction and the limit switch stop position to enable the gate run to the setting limit switch position To change the gate opener from right hand instal...

Страница 17: ...middle of the posts approximately see below diagrams Lock the manual release spanner key locked in readiness for automatic mode Plug the power cord into an approved RCD protected weatherproof outlet...

Страница 18: ...switch stops are correctly installed and well contacted with magnetic limit switch Please refer to page 20 21 for the setting of open and closed limit switch position The ideal closed final position f...

Страница 19: ...al X2 Terminal Set Button Indicator Light X5 Terminal Hall Line Programming and Wiring Any works to the 110V 220V AC must only be performed by a licensed electrician Ensure power is off before any mod...

Страница 20: ...re 20 ANT Extra Antenna GND Extra Antenna Shield COM Common Terminal for External Push Button STP External Stop Push Button Switch PED External Close Push Button Switch OSC External Open Push Button S...

Страница 21: ...Close Limit Switch X4 Terminal 24VBAT Battery Positive 24VBAT Battery Negative Battery Specification 24V 9Ah 12VBAT Battery Positive 12VBAT Battery Negative Battery Specification 12V 9Ah Note and must...

Страница 22: ...frared Photocell is blocked the gate will stop and open immediately to protect user and property security To install photocells connect wiring as per Figure 21 You must remove the wire jumper between...

Страница 23: ...rface Instruction Figure 23 Indicator Lights L0 Green Indicating the control board working status and menu status L1 L5 Red Indicating the settings parameters errors and battery level Set Buttons PROG...

Страница 24: ...o open the gate then release to stop running Press to close the gate then release it to stop running 3 Press PROG button once to exit the manual control mode Indicator light L3 will be off B Operation...

Страница 25: ...e do not move or remove it anymore A Operation Instruction a Press button for 2 sec motor will automatically start it s travel learning b During gate closing the indicator lights will be on from L5 to...

Страница 26: ...andby mode to enter into the first function of remote control management 2 Different functions can be selected through and buttons 3 Press SET button to enter into the corresponding parameter settings...

Страница 27: ...ed to the gate opener can individually control the operation of one opener The rest buttons on this remote control can be used to pair to other openers Figure 25 A Operation Instruction 1 Press and ho...

Страница 28: ...the gate opener will be separately used for gate opening closing and stop Please refer to Figure 26 for the usage for the forth button on the remote control Figure 26 Open Close Stop Pedestrian Mode...

Страница 29: ...e control twice The indicator lights L1 L5 will be on in sequence then all will flicker once and off If an alarm lamp is connected it ll be on for one sec Learning is complete thereafter B Operation G...

Страница 30: ...o L5 4 Press the button which is to be paired on the remote control once The indicator lights L1 L5 will be on in sequence then all will flicker once and off Learning is complete thereafter B Operatio...

Страница 31: ...exit Indicator lights will be off in sequence from L5 to L1 after which indicator lights L1 L5 will be on for one sec B Operation Graphic Illustration Remote Control Quick Learning Remote control quic...

Страница 32: ...the button to be learned on the remote control under the above status The alarm lamp will be off Then remote control learning is complete 3 The system will automatically exit the learning mode after p...

Страница 33: ...t is L5 3 Press or button to adjust the running speed Indicator lights L1 L5 will indicate different speed status The more the indicator lights are on the faster the running speed will be 4 Press SET...

Страница 34: ...Press SET button once to enter into setting mode Indicator lights L1 L5 will show the current slow stop speed The default is L1 4 Press or button to adjust the slow stop speed Indicator lights L1 L5 w...

Страница 35: ...lect the reverse option Indicator light L3 will be steady on 3 Press SET button once to enter into setting mode Indicator lights L1 L5 will show the current setting The default is L2 4 Press or button...

Страница 36: ...y which will extend the service life of gate and gate opener A Operation Instruction 1 Press and hold PROG button for 3 sec to enter into basic menu Indicator light L0 will flicker once then L1 will b...

Страница 37: ...gate is completely open the control board will send the auto close signal to enable the gate to close automatically according to the pre set auto close time A Operation Instruction 1 Press and hold PR...

Страница 38: ...ration L1 L2 L3 L4 L5 Cancel Auto close function L1 L2 L3 L4 L5 L1 L2 L3 L4 L5 L1 L2 L3 L4 L5 L1 L2 L3 L4 L5 L1 L2 L3 L4 L5 Indicator light status Off On Flicker Status Instruction Auto close after 10...

Страница 39: ...s different for users from different regions the control board for this product offers 3 different working modes for users to choose 1 Standard Mode L1 Terminals for external buttons OSC Single button...

Страница 40: ...into advanced menu Indicator light L0 will flicker twice then L1 will be steady on 3 Press SET button once to enter into working mode setting Indicator lights L1 L3 will show the current selection The...

Страница 41: ...anced menu Indicator light L0 will flicker twice then L1 will be steady on 3 Press button once to select acceleration option Indicator light L2 will be steady on 4 Press SET button once to enter into...

Страница 42: ...order to ensure the reliability of the infrared sensor it is requested that the control board performs delay detection to the input signal of infrared sensor When the gate opener receives the opening...

Страница 43: ...ts L1 L3 will show the current setting Table 2 Start up Delay Time 6 Press SET button once to save and system will automatically exit The indicator lights L1 L5 will be on in sequence then all will fl...

Страница 44: ...into basic menu Indicator light L0 will flicker once then L1 will be steady on 2 Press PROG button again for 3 sec to enter into advanced menu L0 will flicker twice then L1 will be steady on 3 Press b...

Страница 45: ...1 Press and hold PROG button for 3 sec to enter into basic menu Indicator light L0 will flicker once then L1 will be steady on 2 Press PROG button again for 3 sec to enter into advanced menu L0 will f...

Страница 46: ...ill flicker once to enter into basic menu setting Press PROG button again for 3 sec indicator light L0 will flicker twice to enter into the advanced menu setting Then press PROG button for 3 sec the i...

Страница 47: ...Press PROG button again for 3 sec to enter into advanced menu L0 will flicker twice then L1 will be steady on 3 Press PROG button for 3 sec for the third time to enter into other menu setting L0 will...

Страница 48: ...eir required There are four types of buzzer this motor will make for different conditions 1 Motor works normally under mains power the buzzer sounds short but long lasting 2 Motor works normally under...

Страница 49: ...button for 3 sec for the third time to enter into other menu setting L0 will flicker three times then L1 will be steady on 4 Press button twice to select buzzer setting option Indicator light L2 will...

Страница 50: ...and A Operation Instruction 1 Press SET button once Indicator lights L1 L5 will indicate the current battery level Table 3 Battery Level 2 Press PROG button once to exit the battery level checking Ind...

Страница 51: ...SET once L1 L5 off Battery Level 11 3V Battery Level 11 7V Battery Level 12 0V L1 L5 will indicate the current battery level Battery Level 12 3V Battery Level 12 6V Off Press PROG once Status Instruc...

Страница 52: ...vel Table 4 Error Instruction Maintenance The gate should be checked every month to make sure it operates normally For the sake of safety each gate is suggested to be equipped with infrared protector...

Страница 53: ...erminal has a jumper wire if connect photocell please ensure the wiring is correct and the photocell type is N C 2 Ensure that the photocell mounting position can be mutually aligned 3 Remove the obst...

Страница 54: ...Instructions for SL500DC SL800DC www gatexpertstore com 49 Drawing and Measurements Figure 30...

Отзывы: