Instructions for SL500DC/SL800DC
www.gatexpertstore.com
32
the different slow stop distance. The more the indicator lights are on, the longer the
distance will be. If the gate is heavy(over 800kg), it is recommended to set it on L4 or L5
to have a better slow stop running. If the gate weight is less than 500kg, it is
recommended to set it on L2 or L1 to have a better slow stop running.
5.
Press “SET” button once to save and system will automatically exit.
The indicator
lights L1-L5 will be on in sequence, then all will flicker once and off.
B.
Operation Graphic Illustration
Auto-close Function Setting (L5)
When the gate is completely open, the control board will send the auto-close signal to
enable the gate to close automatically according to the pre-set auto-close time.
A. Operation Instruction:
1.
Press and hold “PROG” button for 3 sec. to enter into basic menu.
Indicator light L0
will flicker once, then L1 will be steady on.
2.
Press “+” button four times to enter into Auto-close option.
Indicator light L5 will be
steady on.
3.
Press “SET” button once to enter into setting.
Indicator lights L1-L5 will show the
current auto-close time. (The default is all indicator lights off)
Press “PROG” for
3 sec.
L0 flicker once, L1
will be steady on
Press “+” 3 times
L4 will be steady on Press “SET” once
Press “SET” once
Press “+” or “-” to set, LED
will show the setting value
Save and exit
PROG
SET
SET
L1-L5 will be on in
sequence then all
flicker once and off.