201
www.gateway.com
LED information
LED information
The various subsystems in this server include LEDs that can assist you in troubleshooting
your system. See the following table for a description of these LEDs and the information
they provide:
LED Name
Function
Location
Color
Description
Power LED
Identify the
power state of
the system
Front panel
Green
■
Off = Power is off (or S4/S5
with ACPI)
■
On = Power is on (or S0 with
ACPI)
■
Blinking = S1 Low power
state with ACPI
ID
Aid in server
identification
from the back
panel
Front panel and
left back of
system board
Blue
On = Server identification
enabled
System
Status/Fault
Visible fault
warning
Front panel
Green or
Orange
■
On = No fault
■
Green blink = Degraded
■
Orange blink = Non-critical
■
Orange = Critical or
non-recoverable error
Drive status
(general)
Hard drive
activity and fault
status
Front panel
Green or
Orange
■
Green on = Drive initializing
■
Green blink = Drive active
■
Orange on = Drive or slot
failure
■
Orange slow blink =Drive or
slot fault predicted or rebuild
in progress
■
Orange fast blink = Drive
rebuild interrupted or
rebuild on empty slot
Drive status
(individual drives)
Drive activity and
fault status
Individual drive
carriers
Green or
Orange
■
Green blink - Drive active
■
Green and orange
alternating - Drive is on and
is rebuilding RAID, or is on
and in fault condition
■
Orange blink - Drive is off or
in fault condition
■
Unlit - Drive is inactive or no
drive installed in carrier
Memory board
LEDs (8)
Identify condition
of memory board
and DIMMs
On top of each
memory board
Green or
Orange
For location and description,
see
8510702.book Page 201 Thursday, July 7, 2005 11:21 AM
Содержание 9715
Страница 13: ...8 www gateway com Chapter 1 Checking Out Your Gateway Server 8510702 book Page 8 Thursday July 7 2005 11 21 AM ...
Страница 39: ...34 www gateway com Chapter 2 Setting Up Your Server 8510702 book Page 34 Thursday July 7 2005 11 21 AM ...
Страница 197: ...192 www gateway com Chapter 6 Configuring your RAID solutions 8510702 book Page 192 Thursday July 7 2005 11 21 AM ...
Страница 239: ...234 www gateway com Appendix A Server Specifications 8510702 book Page 234 Thursday July 7 2005 11 21 AM ...
Страница 249: ...244 www gateway com Appendix B 8510702 book Page 244 Thursday July 7 2005 11 21 AM ...
Страница 250: ...Appendix C 245 Field Replaceable Unit FRU Kits Available FRU kits 8510702 book Page 245 Thursday July 7 2005 11 21 AM ...
Страница 254: ...Appendix D 249 Extensible Firmware Interface EFI Shell 8510702 book Page 249 Thursday July 7 2005 11 21 AM ...
Страница 259: ...254 www gateway com Appendix D 8510702 book Page 254 Thursday July 7 2005 11 21 AM ...
Страница 277: ...272 www gateway com 8510702 book Page 272 Thursday July 7 2005 11 21 AM ...
Страница 278: ...MAN 9715 SRV USR GDE R0 06 05 ...