134
www.gateway.com
Chapter 4: Installing Components
Replacing a power supply module
Your server uses as many as two hot-swappable redundant power supplies. If two power
supply modules are installed and one of them fails, the other power supply module
supports the server while you replace the failed module. You do not need to turn off the
server or disconnect peripheral devices to replace a failed power supply module in this
configuration. If only one power supply module is installed, the server must be turned
off to replace it.
If you are adding a redundant power supply module to your server, you must update the
FRU/SDR after the installation is complete. For more information, see
.
LED
Location
Description
Power good
LED (green)
Top
This LED is lit whenever the power is turned on
Fault LED
(orange)
Center
This LED is lit when a power rail has failed, even if
the power supply is in a latched state. The only time
this LED is not lit during a fault condition is if the
3.3VSB is lost.
This LED is not lit when the server is turned off.
AC OK LED
(green)
Bottom
This LED is lit when the power supply module is
plugged into an active AC power source.
Warning
The power supply modules in this server contain no user-serviceable
parts. Only a qualified computer technician should service the power
supply modules.
Your server comes with 3-wire AC power cords fitted with the correct
plug style for your region. If this plug does not match the connector
on your surge protector, UPS, or wall outlet, do not attempt to modify
the plug in any way. Use a UPS or wall outlet that is appropriate for
the supplied AC power cords.
Caution
Because of chassis airflow disruption, a power supply module bay
should never be empty for more than two minutes when the server
power is on. Possible damage to system components could result if
the bay is empty for more than five minutes.
If your server is configured with only one power supply module, an
active fan blank must be installed in the second power supply module
bay.
8510702.book Page 134 Thursday, July 7, 2005 11:21 AM
Содержание 9715
Страница 13: ...8 www gateway com Chapter 1 Checking Out Your Gateway Server 8510702 book Page 8 Thursday July 7 2005 11 21 AM ...
Страница 39: ...34 www gateway com Chapter 2 Setting Up Your Server 8510702 book Page 34 Thursday July 7 2005 11 21 AM ...
Страница 197: ...192 www gateway com Chapter 6 Configuring your RAID solutions 8510702 book Page 192 Thursday July 7 2005 11 21 AM ...
Страница 239: ...234 www gateway com Appendix A Server Specifications 8510702 book Page 234 Thursday July 7 2005 11 21 AM ...
Страница 249: ...244 www gateway com Appendix B 8510702 book Page 244 Thursday July 7 2005 11 21 AM ...
Страница 250: ...Appendix C 245 Field Replaceable Unit FRU Kits Available FRU kits 8510702 book Page 245 Thursday July 7 2005 11 21 AM ...
Страница 254: ...Appendix D 249 Extensible Firmware Interface EFI Shell 8510702 book Page 249 Thursday July 7 2005 11 21 AM ...
Страница 259: ...254 www gateway com Appendix D 8510702 book Page 254 Thursday July 7 2005 11 21 AM ...
Страница 277: ...272 www gateway com 8510702 book Page 272 Thursday July 7 2005 11 21 AM ...
Страница 278: ...MAN 9715 SRV USR GDE R0 06 05 ...