1.
Remove crimper, back-up ring, two die
cones, die magnet, hose assembly, mounting
bracket with bolt, jar of Molykote “G” grease,
operating manual, crimp data book and crimp
decals from shipping carton. Locate serial
number on base plate in front of left post and
record on Page 1. Be sure to fill out the
crimper registration card. (By completing the
card and returning it to Gates, you will receive
crimp data updates and full warranty cover-
age.) Remove pump, breather cap and operat-
ing manual from its shipping carton.
2.
Mount crimper so it overhangs a work-
bench (as shown in Photo 1). The back of the
cutout (in the base plate) should be in line
with front of bench. The bench should be 37”
to 42” high, stable and of sturdy construction.
3.
Drill three 3/8” diameter holes as shown
in Illustration 1. Connect the mounting bracket
to top rear of crimper and to the hole farthest
from edge of workbench. Further secure
crimper to workbench using the two
remaining holes.
4.
When crimper is secured to the work-
bench, connect hose assembly between
crimper and pump.
5.
Connect receptacle on short cord of pump
to plug on cord of switch box of the crimper.
If plug and receptacle do not match, do
not try to connect.
Differences in the plug
and receptacle indicate the pump and crimper
have different voltages and should not be
operated.
6.
Remove plug from top of pump reservoir
and replace with breather cap provided. Check
that hydraulic oil is within 1/2” of bottom of
plug opening. If needed, add Dextron II ATF or
equivalent to reservoir.
7.
Verify that switch on pump electrical box is
in “OFF” position. Connect pump power cord
to a 15 amp (minimum) rated electrical circuit.
8.
Move switch on pump electrical box to
“ON” position. This will provide power to the
pump and crimper.
9.
Turn knob on top of crimper switch box to
get a setting of 2.00 on the readout. Cycle
crimper at least 5 times to bleed air from
cylinder and hydraulic system.
3
Mounting
Bracket
Work Bench
Crimper Base
(3) 3/8
Diameter Holes
3-1/4
9-3/4
2
2
Peel and position crimp
decal on the shroud
according to your
preference.
Crimper and pump
voltage must be the
same
or digital readout will be damaged.
WARNING:
Setup
ILLUSTRATION 1
PHOTO 1