1.
Before initiating calibration procedure,
make sure crimper has been cycled five times.
To cycle, dial in a setting of 2.00 and run
crimper down to shutoff with no die set
loaded.
2.
Install the “733” die set to calibrate the
machine using an 8G MegaCrimp
®
coupling.
3.
Set the digital readout setting to 5.20.
(Rotating the knob on top of switch box clock-
wise will increase the number; counterclock-
wise will decrease the number. When chang-
ing the setting, always move to a higher num-
ber then down to the desired setting.
Example: To change from 5.00 to 5.20, move
dial up to 6.00 then down to 5.20.) The
readout figures may jump a number; i.e. 5.20
to 5.19 or 5.21. This will not affect the crimp OD.
4.
Insert the coupling into the die set
approximately 1/8” below top of die. (See
Photo 1.)
5.
Slide the die cone assembly under the
ram until it stops against back locating pins
and push the crimp button and hold. Release
the button immediately when the pump stops.
6.
Remover coupling and measure crimp diame-
ter, which should measure 1.000” ± .003”. (See
Page 9 for Measuring Crimp Diameter.)
7.
If ferrule crimp diameter is not acceptable,
adjust actuator rod. (See Photo 2.)
a. To increase crimp diameter – Hold the
1-1/16” actuator rod while loosening the
3/4” lock nut. Rotate the actuator rod clock-
wise (one full turn of the actuator rod will
change crimp diameter approximately
0.024”). Then tighten the lock nut down.
b. To decrease crimp diameter – Hold the
1-1/16” actuator rod while loosening the
3/4” lock nut. Rotate the actuator rod
counter clockwise (one full turn of the actu-
ator rod will change crimp diameter approxi-
mately 0.024”). Then tighten the lock nut
down.
8.
Repeat steps 3 through 7 to verify correct
crimp diameter.
4
Make sure area under pusher cup is clear of die cone or die sets.
WARNING:
PHOTO 1
PHOTO 2
CLOCKWISE
Do not
over-tighten
lock nut.
CAUTION:
PC 707 Calibration Procedure