5 – LIMITED WARRANTY 
 

GATES guarantee their machines against any faults in materials and workmanship for a period 
of 1 year from the date of purchase.  
 
During this Guarantee period, GATES will repair (or replace as the case may be) at no charge to 
the customer, all of the defective components, provided that the machine is returned to our 
factory.  This warranty does not apply if the machine has been damaged accidentally, misused or 
undergone any repairs or modifications which were not carried out by GATES. GATES is not 
responsible for any injury or damage resulting from direct, indirect or consecutive use of their 
machines, nor for  their machines after the warranty has been expressly or implicitly broken. 
 
This guarantee replaces all other guarantee, including implicit guarantees. 
 
 
 
 
 
 
 
 
 

 
 

 
 
 
Every effort has been made to provide exact and exhaustive information in this guide. However, 
GATES cannot be held responsible for any errors, annulments and modifications made after 
printing has been authorised; or for the use of their products in special or exceptional 
circumstances if a GATES representative was not consulted beforehand to verify the intended 
use. 
 
For further information, contact :

 

Gates Hydraulics Ltd             

Gates Hydraulique S.A. 

Gates Europe N.V.   

Station Road                         B.P. 14   

Dr. Carlierlaan 30 

 

St Neots, Cambs.          

 

F - 69881 Meyzieu-Cedex      

B – 9320 Erembodegem        

PE19 1XA, UK                       TL : +33 (0)4 72 45 12 12                   TL : +32 (0)53 / 76 27 11        
TL : +44 (0)1480 225000 

 

FX : +33 (0)4 72 02 85 24                   FX : +32 (0)53 / 76 27 13        

FX : +44 (0)1480 225350 

 

 

 

 

 

 

 

 

 

 

      

 

 

 

 

 

 

 

 

 

The world’s most trusted name in 

 

 

 

 

 

 

 

                  belts and hose. 

 

 

 

 

 

 

 

 

 

 

 

Содержание MC2000

Страница 1: ...MC2000 OPERATING AND CALIBRATION INSTRUCTIONS...

Страница 2: ...INSTRUCTIONS 8 3 1 SAFETY 8 3 2 UNPACKING INSTALLATION 8 3 3 COMMISSIONING OPERATION 10 3 4 CALIBRATION 11 3 5 POSITION AND FITTING OF THE DIES 12 4 SERVICING AND MAINTENANCE 13 4 1 MAINTENANCE 13 4...

Страница 3: ...MITY The undersigned Company GATES hereby declares that the new equipment referred to hereafter as MC2000 Serial N conforms with the GATES Specification and with the Hygiene and Safety at Work Regulat...

Страница 4: ...ic Pressure 800 bar Dimensions H 310 x W 300 x L 430 mm Weight 41 Kg Crimping Capacity braided hoses from 3 16 to 1 1 4 spiral hoses 1 4 to 1 non skive 1 1 4 skived Pump Manual two speed Oil Tank 0 5...

Страница 5: ...hydraulic power required to move the dies during the crimping process Its characteristics are specially designed to provide the best compromise between available power die movement speed and ease of...

Страница 6: ...upling to be crimped onto the flexible hose It comprises the following elements see figure 2 crimping head body 6 sets of dies 7 a hollow piston moved by the oil pressure 8 eight return springs 5 a cr...

Страница 7: ...ies of thermal body and surface treatments so that they can resist the large loads and wear through friction is prevented Precise guiding is ensured by means of two Teflon Bronze bearers on the piston...

Страница 8: ...he packaging is not damaged when opening it so that it can be stored Lift the box cover then remove the screws positioned at the bottom of the packaging uprights remove the uprights from the box The c...

Страница 9: ...MC2000 USER GUIDE 9 Figure 4 Identification diagram...

Страница 10: ...to check the battery 6 is not flat and that the indicator light 7 works correctly Place the hose together with its coupling inside the crimping head 8 whilst respecting the position of the coupling i...

Страница 11: ...eter and the calibration diameter of 26 0 mm 2 Open the crimping head to its maximum 3 Unscrew the two M6 screws which hold the stop strip on the back of the piston Fig 2 2 then remove the strip Fig 2...

Страница 12: ...S In order to crimp GATES couplings correctly onto GATES hoses it is necessary to adhere to the installation positions of the dies and to the crimping positions below or Fig 5 Crimping positions and i...

Страница 13: ...ybdenum bisulfide this product is provided with the machine and is available from GATES 7482 19957 Lubricate after every 100 crimping operations as indicated below Procedure Lift the back of the die h...

Страница 14: ...HE BATTERY The end of crimping indicator light operates by way of a type 6LR 61 9 Volt battery Procedure Using the lubrication tool apply slight pressure onto the battery casing tray Pull the tray to...

Страница 15: ...g 2 Pge 6 MC2000 9088 Anti extrusion bush D 185 7482 19839 1 Item 16 Fig 2 Pge 6 MC2000 9085 O ring D 164 45 x 5 33 7482 19840 1 Item 15 Fig 2 Pge 6 MC2000 9086 O ring D 139 07 x 5 33 7482 19841 1 Ite...

Страница 16: ...r the warranty has been expressly or implicitly broken This guarantee replaces all other guarantee including implicit guarantees Every effort has been made to provide exact and exhaustive information...

Отзывы: