b. Use Calibration equation to determine
approximate new setting.
(
)
Actual
COD -
Target
COD
x 22 +
Adjusted
Setting
Published
Setting
=
Example:
(1.010 - 1.000) X 22 + 1.23 = 1.45
Changing the dial vernier number by approximately
.02 will change crimp diameter .001”.
c. Using the Allen head wrench included in the
Accessory Kit, remove the dial vernier by
loosening the set screw located at bottom on
black knob of dial vernier.
■
If crimp was too tight, unlock dial vernier and lower
setting according to above calibration equation.
Lock in place.
■
If crimp was too loose, unlock and raise setting.
Lock in place.
d. Reinstall dial vernier and tighten set screw
using Allen wrench.
e. Unlock and reset dial vernier to 1.23.
7. Repeat calibration steps until published crimp diameter is
achieved. Crimper is now calibrated.
ADJUSTMENT PROCEDURE
Should the actual crimp diameter NOT be within the tolerance
specified in the Crimp Data Charts, check the calibration of the
crimper. If the calibration is correct, a slight adjustment of the
digital readout may be necessary. To obtain a smaller crimp
diameter, change the digital readout to a smaller number, or vice
versa. Changing the digital readout by .05 (Example: 5.50 to
5.55) will change the crimp diameter by .001”.
(
)
Actual
COD -
Target
COD
x 22 +
Adjusted
Setting
Published
Setting
=
Remember
to record your Actual adjusted crimp setting in the
column provided in the crimp data chart.
69
DOWNLOAD THE ECRIMP APP OR GO TO WWW.GATES.COM/ECRIMP
PO
WER STEERING
MC 4-20 DD & PS
GC16XD
PC707/SC32
GC32-XD/FLEX
GC96
SWA
GING
GENERAL
GATES
CALIBRATION & ADJUSTMENT PROCEDURES