SC32 CALIBRATION PROCEDURE
1. Install the “.733” die set to calibrate the machine using an 8G
Megacrimp
®
coupling.
2. Set the Dial Vernier setting to 5.20. Rotating the dial clockwise
will increase the number and rotating it counterclockwise will
decrease the number. When changing the setting, always move
to a higher number then down to the desired setting
■
Example: To change from 5.00 to 5.20, move the
Dial Vernier up to 6.00 then down to 5.20.
3. Insert the coupling into the die set approximately 1/8 inch below
the top of the die (See Photo 1).
PHOTO 1
4. Push and hold the start/stop switch until the pump stops.
5. Remove the coupling and measure the crimp diameter which
should measure 1.000 +/- .003 inches. See page 8 for
measuring crimp diameter.
PHOTO 2
6. If ferrule crimp diameter is not acceptable adjust the Dial
Vernier (See Photo 2).
■
To increase the crimp diameter, hold the Dial Vernier
barrel with a 5/16 inch open end wrench and rotate
the stem out of the barrel with a 5/32 inch hex key
wrench.
■
To decrease the crimp diameter, hold the Dial
Vernier barrel with a 5/16 inch open end wrench
and rotate the stem into the barrel
7. Repeat steps 2 through 5 to verify the correct crimp setting.
126
DOWNLOAD THE ECRIMP APP OR GO TO WWW.GATES.COM/ECRIMP
GENERAL
SWA
GING
GC32-XD/FLEX
GC96
PC707/SC32
GC16XD
MC 4-20 DD & PS
PO
WER STEERING
GATES
CALIBRATION & ADJUSTMENT PROCEDURES