Diagram 3 Terminal blocks
Terminal block
Mark
Description
AC IN
Battery charge power supply input (i.e. transformer
output: 16 V AC/30 VA)
JX1
+ –
No connection
12, 0, 5
Power supply output (DC12V, GND, DC5V)
RF
No connection
JX2
DI
Keypad signal input
12, 0
Power supply output (DC12V, GND)
IR
Infrared photocell input
JX3
BI
Open signal input
JX4
Z Z
Alarm lamp (DC12V, Max.10W)
OP, CO, CL
Limit switch (open limit, common, close limit)
JX5
D, D
Motor
1
It is used to adjust the auto-close time and pedestrian
mode.
2
No connection
3
No connection
SW
(DIP-switch)
4
It is used for open and close limit adjustments.
LED1
Battery charge indicator light
LED2
Status indicator light
LEARN
Learn button
VR2
Set the open force
Others
VR3
Set the close force
Infrared
input(N.C.)
Open signal
input(N.O.)
Keypad signal
input(N.O.)
IR
0
12
12
0
BI
JX3
JX2
RF
5
0
12
DI
Limit switch wires and motor wires have been connected before delivery.
JX5
OP
CO
CL
D
D
Open (N.C.)
COM
Close(N.C.)
Limit switch
Motor
Fig 16.