background image

GM720A-YF A

/C Service Station

5

Description:

Flushing

This function include flushing and
recovery process.

Database

Check the amount of Refrigerant & oil

Recovery

Recovery the refrigerant of A/C
system.

Equipment Maintanance

Exchange dry-filter, Pipe-line
cleanning, Calibration load cell.

Vacuum

Timing vacuum.

Discharge non-condensable gases

Avoid high-pressure alarm.

New oil adding

Fill the new oil into A/C system.

System function

Supply,Parameter setting,Exchange
filling tank,Change refrigerant type

Recharging

Recharge quantitative.

Equipment info

System info,Servicer info, Equipment
info.

Auto. Mode

Automatically all the process.

Help

Descriptions of the alarming code.

5) Flushing

A

By this function, it will be able to clean out the refrigerant oil and oil sludge to exchange the refrigerant entirely to improve
the performance of compressor. And also it will recover the refrigerant remained in the A/C system.

B

Before flushing the pipeline of automotive A/C system, please turn on A/C system and run it for 5 to 10
minutes. And set it as the lowest temperature and medium wind.

C

Turn off the automotive air conditioning.

Warning: do not start the air conditioning during the flushing process! Otherwise, it easily causes
damages to the air-conditioning and risk of accident!

D

In order to achieve good flushing performance, the flushing time should be more than 30 minutes.

Note: The flushing time does not include the time of recovery process. Once the flushing is
finished, the machine will run the recovery function automatically.

E

Operations:

E-1: Select the Flushing Function

and press the ENTER key.

E-2: Set the flushing time.
E-3: Press the ENTER key to start.

F

When finished, it’ll stop automatically.

Notice: it’s normal for that there have action sound of the solenoid valve during the working

Содержание GM720A-YF

Страница 1: ...GM720A YF A C Service Station GM720A YF A C System Maintenance Centre...

Страница 2: ...such as cooling fans alternators and heating components etc to avoid harm F Wear protective clothing gloves and goggles G As automotive air conditioning pipe flushing the operator must be fully famili...

Страница 3: ...ew oil adding 6 9 Recharging 7 10 Auto Mode 7 11 Database 8 12 Equipment Maintanance 8 12 1 Exchange dry filter 8 12 2 Clean pipe of the unit 8 12 3 Calibration of load cell 8 12 4 Change vacuum pump...

Страница 4: ...prove the cleaning effect D Using large size glass tube with LED backlighting can effectively observe the entire cleaning process E Vertically installing the HP LP gauges let the operator be able to o...

Страница 5: ...unctions A Automatic flushing B Automatic recovering recycling C Automatic manual used oil drain D Vacuum timing E Automatic manual new oil injection F Quantitative recharging G Auto mode H Database I...

Страница 6: ...rts descriptions HP gauge Operation panel LP gauge Dry filter service port TP gauge Switch for new oil adding New oil bottle Switch for used oil discharge Used oil bottle Printer LCD display HP Port L...

Страница 7: ...lease refer to the chapter of Refrigerant supply D Please read this user manual carefully before operating 3 Preparations before Operation A To check if there has enough refrigerant in the tank The vo...

Страница 8: ...irely to improve the performance of compressor And also it will recover the refrigerant remained in the A C system B Before flushing the pipeline of automotive A C system please turn on A C system and...

Страница 9: ...eds 15 minutes at least for the air conditioning only with front wind and 20 minutes for with the front and rear wind C Operations C 1 Select the Vacuum Function and press the ENTER key C 2 Set the va...

Страница 10: ...ng Note In the recharging process if shows the menu it means that you need to turn on the car air conditioning to complete the recharging process Later you should supply new refrigerant into the tank...

Страница 11: ...er 12 2 Clean pipe of the unit A After a period of use such as 2months it should be run this function B It can clean up the pipe line of the machine 12 3 Calibration of load cell A When the load cell...

Страница 12: ...the High pressure Alarm it need do this function B We advise that it should be done once a month 14 System function 14 1 Supply main tank internal tank A If the refrigerant amount in the main tank is...

Страница 13: ...tank upside down M2 2 Connect the HP or LP coupler to the supplying connecter M2 3 Select the Recovery function and run it M2 4 When you see the total amount more than 4 5kg close the valve of the re...

Страница 14: ...machine 15 2 Servicer info Here you can set and check the servicer and dealer information The way for setting Press and keys at same time into the setup state Use the and keys to select position Use...

Страница 15: ...GM720A YF A C Service Station 12 16 Help Here you can check all of the help messages...

Страница 16: ...GM720A YF A C Service Station 13 Declare We reserve the right to modify the contents of this document without prior notice to our customers...

Отзывы: