background image

GM720A-YF A

/C Service Station

8

11) Database

Here you can read the refrigerant type and filling amount and the refrigerant oil type and filling

amount of the automotive.

12) Equipment Maintanance

12-1) Exchange dry filter

A

The dry filter must be exchange when it reaches the life time. There will give a message.

B

If not exchange the dry-filter timely, it will not be able to run the recovery, flushing and supplying functions.

C

Operations:

C-1:

Please check the ID of the dry-filter at the label. Which is the SN.

C-2:

Select Exchange dry-filter Function and press ENTER key.

C-3:

Input the ID.

C-4:

And then do step by step as the information.

Note: Please attention the mounting direction of the dry-filter.

12-2) Clean pipe of the unit

A

After a period of use, such as 2months, it should be run this function.

B

It can clean up the pipe line of the machine.

12-3) Calibration of load cell

A

When the load cell is not precise, it needs to be calibrated.

B

You need input the password 1510 before use this function.

C

If do the calibration of main tank load cell, please prepare a 10~15kg weight.
If do the calibration of oil bottle load cell, please prepare a 1kg weight.
If do the calibration of auxiliary tank load cell, please prepare a 10~15kg weight.

D

Follow the prompts step by step.

Note: if here have some programs, please check according to the messages.

12-4) Change vacuum pump oil

A

When the pump oil became cream or machine display maintenance message, the vacuum pump oil must

be changed.

B

If not change the pump oil in time, the vacuum pump will be easily damaged.

C

Steps:

C-1: Open the back-down cover.

Содержание GM720A-YF

Страница 1: ...GM720A YF A C Service Station GM720A YF A C System Maintenance Centre...

Страница 2: ...such as cooling fans alternators and heating components etc to avoid harm F Wear protective clothing gloves and goggles G As automotive air conditioning pipe flushing the operator must be fully famili...

Страница 3: ...ew oil adding 6 9 Recharging 7 10 Auto Mode 7 11 Database 8 12 Equipment Maintanance 8 12 1 Exchange dry filter 8 12 2 Clean pipe of the unit 8 12 3 Calibration of load cell 8 12 4 Change vacuum pump...

Страница 4: ...prove the cleaning effect D Using large size glass tube with LED backlighting can effectively observe the entire cleaning process E Vertically installing the HP LP gauges let the operator be able to o...

Страница 5: ...unctions A Automatic flushing B Automatic recovering recycling C Automatic manual used oil drain D Vacuum timing E Automatic manual new oil injection F Quantitative recharging G Auto mode H Database I...

Страница 6: ...rts descriptions HP gauge Operation panel LP gauge Dry filter service port TP gauge Switch for new oil adding New oil bottle Switch for used oil discharge Used oil bottle Printer LCD display HP Port L...

Страница 7: ...lease refer to the chapter of Refrigerant supply D Please read this user manual carefully before operating 3 Preparations before Operation A To check if there has enough refrigerant in the tank The vo...

Страница 8: ...irely to improve the performance of compressor And also it will recover the refrigerant remained in the A C system B Before flushing the pipeline of automotive A C system please turn on A C system and...

Страница 9: ...eds 15 minutes at least for the air conditioning only with front wind and 20 minutes for with the front and rear wind C Operations C 1 Select the Vacuum Function and press the ENTER key C 2 Set the va...

Страница 10: ...ng Note In the recharging process if shows the menu it means that you need to turn on the car air conditioning to complete the recharging process Later you should supply new refrigerant into the tank...

Страница 11: ...er 12 2 Clean pipe of the unit A After a period of use such as 2months it should be run this function B It can clean up the pipe line of the machine 12 3 Calibration of load cell A When the load cell...

Страница 12: ...the High pressure Alarm it need do this function B We advise that it should be done once a month 14 System function 14 1 Supply main tank internal tank A If the refrigerant amount in the main tank is...

Страница 13: ...tank upside down M2 2 Connect the HP or LP coupler to the supplying connecter M2 3 Select the Recovery function and run it M2 4 When you see the total amount more than 4 5kg close the valve of the re...

Страница 14: ...machine 15 2 Servicer info Here you can set and check the servicer and dealer information The way for setting Press and keys at same time into the setup state Use the and keys to select position Use...

Страница 15: ...GM720A YF A C Service Station 12 16 Help Here you can check all of the help messages...

Страница 16: ...GM720A YF A C Service Station 13 Declare We reserve the right to modify the contents of this document without prior notice to our customers...

Отзывы: