background image

                                                       

GM-820A-Dual        A/C SYSTEM MAINTENANCE CENTRE-DUAL   

 

NOTE: 

1)  Carefully read the user manual before using, and keep it well for future reference. 

2)  Carefully check the device parts list before using. For any doubt, contact GAT MACHINERY distributor 

immediately. 

3)  Due to the product upgrade, tiny difference between the user manual and the device will not be further 

noticed. Take the device as standard. 

 

Copyright reserved! Without written agreement from GAT Machinery Co., Ltd (Hereinafter refer to 

"GATMATIC "), any company or person is not allowed to copy and duplicate this user manual in any format 

(electronic, mechanical, video, record or other formats).The user manual is designed only for GATMATIC 

products. Any consequence caused by using the user manual to guide other device operation is not under 

the responsibility of GATMATIC. 
 
GATMATIC and its branches are not responsible for the fees and expense of the device damage and loss 

due to private accident or from third party, misuse and abuse of the device, unauthorized change and repair, 

or any operation and maintenance not following GATMATIC standard.   
 
GATMATIC  is  not  responsible  for  device  damage  or  problem  due  to  the  usage  of  any  optional  parts  or 

consumables instead of GATMATIC original products or GATMATIC recognized products.   
 
Declaration: Other product names mentioned in the user manual are aimed to describe the device usage. 

The registered trademarks still belong to the original company.   
 
The device is for professional technicians or maintenance and repair personnel. 
 

Registered Trademark 

GAT MACHINERY has registered its trademark in China and several other countries, logo is

Other  GATMATIC  trademarks,  service  marks,  dot  names,  Icons,  company  names  mentioned  in  the  user 

manual  all  belong  to  GATMATIC  and  its  subsidiaries.  In  those  countries  where  GATMATIC  trademark, 

service  mark,  dot  name,  icon,  company  name  not  registered  yet,  GATMATIC  declaim  the  right  for  its 

unregistered  trademark,  service  mark,  dot  name,  icon,  and  company  name.  Trademarks  of  the  other 

products  and  company  names  mentioned  in  the  user  manual  still  belong  to  original  registered  company. 

Without written agreement from the owner, no person is allowed to use the trademark, service mark, dot 

name,  icon  and  company  name  of  GATMATIC  or  of  other  mentioned  companies.  You  can  visit 

http://www.gattek.com to get contact with GATMATIC for the written agreement on the usage of the User 

Manual.   

 

 

 

 

 

 

 

Содержание GM-820A-Dual

Страница 1: ...GM 820A Dual A C SYSTEM MAINTENANCE CENTRE DUAL 1 GM 820A Dual A C System Maintenance Centre R1234a R1234yf...

Страница 2: ...TIC is not responsible for device damage or problem due to the usage of any optional parts or consumables instead of GATMATIC original products or GATMATIC recognized products Declaration Other produc...

Страница 3: ...lternators and heating components etc to avoid harm E Wear protective clothing gloves and goggles F As automotive air conditioning pipe flushing the operator must be fully familiar with automotive air...

Страница 4: ...12 8 New oil adding 12 9 Recharging 13 10 Auto Mode 14 11 Database 14 12 Equipment Maintenance 14 12 1 Exchange dry filter 15 12 2 Clean pipe of the unit 15 12 3 Calibration of load cell operate by p...

Страница 5: ...nd pulse flushing functions which greatly improve the cleaning effect E Using large size glass tube with LED backlighting can effectively observe the entire cleaning process F Vertically installing th...

Страница 6: ...Automatic recovering recycling E Automatic manual used oil drain F Vacuum timing G Automatic manual new oil injection H Quantitative recharging I Each function can operate independently J Auto mode K...

Страница 7: ...1 Parts descriptions HP gauge Alarm LCD display Keys R134a HP port R1234yf HP port LP gauge Printer R134a LP port R1234yf LP port Window Power switch Power socket R134A Tank R1234YF Tank Used oil bot...

Страница 8: ...cale handle the suspended state As shown in the figure below B Connect the power supply and power on Please operation as following C Set the language select one and press ENTER C Set the units select...

Страница 9: ...lease read this user manual carefully before operating 3 Preparations before Run Flushing function A Check the refrigerant type of the automobile air conditioning and connect the right couplers to the...

Страница 10: ...ompts If the process is terminated artificially it will can t be into the main function and back to the last Interface D After completion enter the function interface Description Flushing Recovery Thi...

Страница 11: ...easily causes damages to the air conditioning and risk of accident D In order to achieve good flushing performance the flushing time should be more than 20 minutes General the cleaning time for single...

Страница 12: ...his function it will clean the water vapor out from the A C system B It should be more than 15 minutes Generally it needs 15 minutes at least for the air conditioning only with front wind and 20 minut...

Страница 13: ...d release the key to stop C 3 2 If set the filling amount press ENTER key after set and it will stop automatically 9 Recharging A Select the Recharging Function and press the ENTER key B Set the recha...

Страница 14: ...full automatically after setting the parameters B Before running must drain out the used oil entirely and fill enough new oil into the new bottle Pay attention to the oil type C Operations C 1 Select...

Страница 15: ...nt Maintenance C 2 Select Clean Pipe of The Unit function and press ENTER key C 3 Connect the hoses and couplers well to the coupling side of the equipment and open the couplers C 4 And then press ENT...

Страница 16: ...Operations C 1 Power on select refrigerant type then select Equipment Maintenance C 2 Select Vacuum System Pipeline function and press ENTER key C 3 Connect the hoses and couplers well to the coupling...

Страница 17: ...le can be extended Or when the machine appear the High pressure Alarm it need do it immediately C Operations C 1 Remove the rear refrigerant tank and place it aside Note do not remove any pipes C 2 Op...

Страница 18: ...resh refrigerant tank to the LP port of equipment Note it should connect to the liquid port of fresh refrigerant tank If has no liquid port please place the fresh refrigerant tank upside down B 4 Open...

Страница 19: ...status of the machine 15 2 Servicer info Here you can set and check the servicer and dealer information The way for setting Press and keys at same time into the setup state Use the and keys to select...

Страница 20: ...0A Dual A C SYSTEM MAINTENANCE CENTRE DUAL 20 16 Help Here you can check all of the help messages Declare We reserve the right to modify the contents of this document without prior notice to our custo...