background image

                                                       

GM-820A-Dual        A/C SYSTEM MAINTENANCE CENTRE-DUAL   

12 

 

Notice:  it

’s normal for that there have action sound of the solenoid valve during the working 

process. Please do not stop it. The used oil can be drained out automatically. 

Warning: In case of sudden power failure or accidental termination during the  Flushing-Recovery 

process, please re select the Flushing-Recovery function. The cleaning time can be set shorter and 

then run again. It is important not to operate other functions. 

6) Recovery/Recycling 

A. 

By this function, it will recover the refrigerant remained in the A/C system. 

B. 

Operations:                                                                                                 

B-1: Select the Recovery Function 

  and press the ENTER key. 

B-2: Press the ENTER key to start. 

B-3: After 

recovery over, it’ll drain the used oil automatically. 

C. 

When finished, it will discharge the separated used oil, and then stop automatically.   

7) Vacuum 

A.  By this function, it will clean the water vapor out from the A/C system. 

B.  It should be more than 15 minutes. Generally, it needs 15 minutes at least for the air conditioning only 

with front wind and 20 minutes for with the front and rear wind. 

C.  Operations: 

C-1: Select the Vacuum Function 

  and press the ENTER key. 

C-2: Set the vacuum time. 

C-3: Press the ENTER key to start. 

D.  When fi

nished, it’ll stop automatically. 

8) New oil adding 

A.  It must be able to do after vacuum process. 

B.  Pour new oil into the new oil bottle.

 

 

Note:   

1)  Add  new  oil  more  20ml  than  the  used  oil  drained  out  to  avoid  the  air  into  the  air 

conditioning system.   

2) 

Pour the new oil into the corresponding oil bottle. 

PAG oil into the PAG bottle and POE oil into the 

POE  bottle.  The  two  types  of  oil  cannot  be  mixed,  otherwise  it  will  cause  damage  to  the  air 

conditioning  system.  Please  check  the  vehicle  technical  manual  or  label,  do  not  add  the  wrong 

type!

 

3) 

If a non-vacuum state is detected, the function cannot be run.

 

C.  Operations: 

C-1: Select the New oi adding Function 

  and press the ENTER key. 

Содержание GM-820A-Dual

Страница 1: ...GM 820A Dual A C SYSTEM MAINTENANCE CENTRE DUAL 1 GM 820A Dual A C System Maintenance Centre R1234a R1234yf...

Страница 2: ...TIC is not responsible for device damage or problem due to the usage of any optional parts or consumables instead of GATMATIC original products or GATMATIC recognized products Declaration Other produc...

Страница 3: ...lternators and heating components etc to avoid harm E Wear protective clothing gloves and goggles F As automotive air conditioning pipe flushing the operator must be fully familiar with automotive air...

Страница 4: ...12 8 New oil adding 12 9 Recharging 13 10 Auto Mode 14 11 Database 14 12 Equipment Maintenance 14 12 1 Exchange dry filter 15 12 2 Clean pipe of the unit 15 12 3 Calibration of load cell operate by p...

Страница 5: ...nd pulse flushing functions which greatly improve the cleaning effect E Using large size glass tube with LED backlighting can effectively observe the entire cleaning process F Vertically installing th...

Страница 6: ...Automatic recovering recycling E Automatic manual used oil drain F Vacuum timing G Automatic manual new oil injection H Quantitative recharging I Each function can operate independently J Auto mode K...

Страница 7: ...1 Parts descriptions HP gauge Alarm LCD display Keys R134a HP port R1234yf HP port LP gauge Printer R134a LP port R1234yf LP port Window Power switch Power socket R134A Tank R1234YF Tank Used oil bot...

Страница 8: ...cale handle the suspended state As shown in the figure below B Connect the power supply and power on Please operation as following C Set the language select one and press ENTER C Set the units select...

Страница 9: ...lease read this user manual carefully before operating 3 Preparations before Run Flushing function A Check the refrigerant type of the automobile air conditioning and connect the right couplers to the...

Страница 10: ...ompts If the process is terminated artificially it will can t be into the main function and back to the last Interface D After completion enter the function interface Description Flushing Recovery Thi...

Страница 11: ...easily causes damages to the air conditioning and risk of accident D In order to achieve good flushing performance the flushing time should be more than 20 minutes General the cleaning time for single...

Страница 12: ...his function it will clean the water vapor out from the A C system B It should be more than 15 minutes Generally it needs 15 minutes at least for the air conditioning only with front wind and 20 minut...

Страница 13: ...d release the key to stop C 3 2 If set the filling amount press ENTER key after set and it will stop automatically 9 Recharging A Select the Recharging Function and press the ENTER key B Set the recha...

Страница 14: ...full automatically after setting the parameters B Before running must drain out the used oil entirely and fill enough new oil into the new bottle Pay attention to the oil type C Operations C 1 Select...

Страница 15: ...nt Maintenance C 2 Select Clean Pipe of The Unit function and press ENTER key C 3 Connect the hoses and couplers well to the coupling side of the equipment and open the couplers C 4 And then press ENT...

Страница 16: ...Operations C 1 Power on select refrigerant type then select Equipment Maintenance C 2 Select Vacuum System Pipeline function and press ENTER key C 3 Connect the hoses and couplers well to the coupling...

Страница 17: ...le can be extended Or when the machine appear the High pressure Alarm it need do it immediately C Operations C 1 Remove the rear refrigerant tank and place it aside Note do not remove any pipes C 2 Op...

Страница 18: ...resh refrigerant tank to the LP port of equipment Note it should connect to the liquid port of fresh refrigerant tank If has no liquid port please place the fresh refrigerant tank upside down B 4 Open...

Страница 19: ...status of the machine 15 2 Servicer info Here you can set and check the servicer and dealer information The way for setting Press and keys at same time into the setup state Use the and keys to select...

Страница 20: ...0A Dual A C SYSTEM MAINTENANCE CENTRE DUAL 20 16 Help Here you can check all of the help messages Declare We reserve the right to modify the contents of this document without prior notice to our custo...

Отзывы: