MDE-4363G Atlas™ Fuel Systems Owner’s Manual · August 2018
Page 3-23
Battery Backup Power Supply for Series 9800
The Atlas Fuel System
Battery Backup Power Supply for Series 9800
Atlas Commercial 9800 Series models (made after August 2011) are designed to display the
last transaction data for a minimum of 15 minutes (after power loss) without the need of a
battery or battery backup power supply.
Information for ATC (Series 9800 Only)
By activating the magnet located at the opposite side of the totalizer, various items will appear
on the display.
On the ATC Status Display, the rightmost digit (2) indicates whether the temperature
compression is enabled or not. If enabled, it shows which product is being dispensed.
• 0=temperature compensation enabled
• 1=product is gasoline and compensation enabled
• 2=product is diesel and compensation enabled.
Note: Not used in the Atlas DEF 9862 units.
On the ATC Status Display, the leftmost digits (842) are error indicators which are blank when
the corresponding error condition is not active. When any of the following digits are
displayed:
• 8=temperature probe fault is detected
• 4=pulser error occurred
• 2=exceptional reset was detected
1.
Volume Display
Displays uncompensated volume
0023.43
2.
Probe Temperature
Display Displays probe temperature in Celsius only
023.2
3.
Flow Rate Display
Displays Flow Rate (in LPM only)
189.2
4.
Software Version Display
Displays software version number
1.30
5.
ATC Status Display
Displays ATC Status
842.2