Multi Gas Clip Simple Plus User’s Manual

UM MGC-S-PLUS v1.00a 

Portable gas detectors you can count on

17 of 18

Size

4.75 H x 2.75 W x 1.25 D in. (120.65 x 69.85 x 31.75 mm.)

Weight

7.675 oz. (220.2 g) 

Temperature

-4˚F to +122˚F (-20˚C to +50˚C)

Humidity

5% to 95% RH (non-condensing) 

Battery Life

1095 days continuous 

based on an average of 1 minute/day of alarm condition 

Alarms

Visual, Vibrating, Audible (minimum 95dB)

Low, High, STEL, TWA and OL (Over Limit) 

LEDs

4 Red alarm bar LEDs 

Yellow backlight (activated on button press)

Red backlight (activated on alarm condition)

Yellow Maintenance Notification LED 

Display

Alphanumeric Liquid Crystal Display (LCD) 

Logs

50 Bump Tests 

50 Events 

50 Calibrations 

Continuous 1-second data logging (typical capacity > 2 months) 

Tests

Full function self-test upon activation 

Sensors, battery and circuitry tests run continuously 

Ingress Protection

IP 68

Warranty

Full 3 years

Gases

Gas

Range

Resolution

Accuracy*

T

90

*

H

2

S

0 – 100 ppm

0.1

<2 ppm

<30s

CO

0 – 500 ppm

1

<5 ppm

<30s

Combustible

0 – 100% LEL

0.1

See Table 1, page 18

<30s

O

2

0 – 30% vol.

0.1

<0.7% vol.

<15s

Sensor Type

H2S, CO, O2: Single plug-in electrochemical cell

Combustible (LEL): Soldered infrared (IR)

User Options

User Message, Language, Low Alarm, High Alarm, STEL Alarm, TWA Alarm, TWA Method, TWA Interval, STEL 

Interval, SAFE, Maintenance Notification, Self-test Lock,  Dock Lock, Sensor Enable/Disable, Calibration 

Interval, Bump Interval, Calibration Gas, %-by-volume, Latching Alarms, Life Display and Off Lock

Approvals

CSA:                  

Class I, Division 1, Group A, B, C, and D

                           Class I, Zone 0, A/Ex ia IIC T4 Ga

                           C22.2 No. 152-M1984 

                           ANSI/ISA S12.13

ATEX:

              SIRA 16ATEX2288

                           CE 0518 

 II 1 G Ex ia IIC T4 Ga

                           (-20°C  ≤ Ta ≤ +50°C)

                           EN 60079-0:2012/A11:2013

                           EN 60079-11:2012

IECEx:               

CSA 16.0038

                           Ex ia IIC T4 Ga

                           IEC 60079-0:2011

                           IEC 60079-11:2011 

DETECTOR SPECIFICATIONS

*Sensor performance is dependent on many factors, including temperature, humidity, sensor age, filter cleanliness, gas 
delivery, and calibration accuracy. Typical performance will be better than the given limits under most circumstances.

Содержание Multi Gas Clip Simple Plus

Страница 1: ...UM MGC S PLUS v1 00a Portable gas detectors you can count on 1 of 18 Multi Gas Clip Simple Plus G A S C L I P T E C H C O M User s Manual...

Страница 2: ...4 Off Mode 4 Alarms 5 Alarm Behavior 5 Default Alarms 5 Detector Menus 6 Main Menu 6 Status Menu 6 Option Menu 7 Adjustable Options 7 Detector Maintenance 9 Battery 9 Bump Testing 9 Manual Bump Test...

Страница 3: ...the detector to sensor poisons such as but not limited to alcohol and citrus based products Exposure to poisons may impair the accuracy and or response time of the detector If suspected sensor poisoni...

Страница 4: ...Ports 4 O2 Sensor 5 Dual Tox Sensor 6 Audible Alarm Port 7 Display 8 Alarm Bar LEDs 9 Maintenance LEDs 10 Infrared IR Communication Window 11 Alligator Clip with Safety Ring 12 Certification Label 13...

Страница 5: ...n Test Mode icon 3 will appear and flash indicating it is time to apply gas The Battery Indicator 4 is displayed as a battery icon which is solid as long as the battery is not low The battery won t ne...

Страница 6: ...r the sensor reading while it is stabilizing and being self tested Once all sensors have completed the warm up and stabilization sequence 65 seconds the detector is fully operational and ready to dete...

Страница 7: ...ry outline only 20 Minutes remaining single beep flash battery outline only 10 Minutes remaining single beep flash battery outline flashes 5 Minutes remaining continuous beep flash every 5 seconds Exp...

Страница 8: ...ill immediately return to normal operation Status Menu The Status Menu is accessed by pressing the Power Menu Button once during the SHOW STATUS prompt The detector will display in the following order...

Страница 9: ...is GAS CLIP TECHNOLOGIES Alarm Limits This option allows you to set sensor low and high alarm limits Each sensor contains separate alarm threshold values that tell the detector when to go into alarm...

Страница 10: ...be adjusted only with the GCT IR Link by Volume CH4 Allows the detector to display gas readings as by volume CH4 rather than LEL The conversion rate can be configured by specifying what the methane co...

Страница 11: ...nual Bump Test Instructions Press the Power Menu Button two separate times in quick succession double tap to access the Main Menu The display will then show in the following order When the screen disp...

Страница 12: ...MGC S Calibration Cap and the detector will return to normal operation after a short period of time The bump due date will be automatically reset based on the new bump date The bump test will be recor...

Страница 13: ...failed a bump test be used During a manual bump test the audible visual vibrating prompting to apply gas will continue for approximately two minutes If gas is not applied within the two minutes then...

Страница 14: ...is detected and as the detector adjusts the calibration parameters Once calibration is complete the detector will display the next calibration date before returning to normal alarming operation If a...

Страница 15: ...first bump test and so on Bump tests are differentiated from normal events when the alarm condition occurs inside of an MGC Simple Clip Dock or when the detector is manually bump tested according to t...

Страница 16: ...ndow lined up approximately 2 3 inches apart 1 Open GCT IR Link Software downloaded for free from www gascliptech com under Resources tab 2 Click on Download Logs icon at the top left corner 3 Select...

Страница 17: ...MGC S CSK Hard sided Carrying Case with Foam Insert 1 ft Sampling Probe Air Stone Particulate Filter MGC S Calibration Cap 10 ft Sampling Hose and 3 ft Calibration Test Hose with Quick Connect Hand A...

Страница 18: ...ox Sensor P N MGC SE 4DT O2 Sensor P N MGC SE O2 Replacement Filters Filter Pack of 10 P N MGC S FILTER 10 Filter Pack of 2 P N MGC S FILTER 2 Various authorized replacement spare parts for Multi Gas...

Страница 19: ...ge Resolution Accuracy T90 H2S 0 100 ppm 0 1 2 ppm 30s CO 0 500 ppm 1 5 ppm 30s Combustible 0 100 LEL 0 1 See Table 1 page 18 30s O2 0 30 vol 0 1 0 7 vol 15s Sensor Type H2S CO O2 Single plug in elect...

Страница 20: ...s and any other applicable recommendations of GCT 2 The buyer promptly notifying GCT of any defect and if required promptly making the product available for correction No goods shall be returned to GC...

Отзывы: