Remove three (3) screws that hold controller cover;
¥
Use synchronization wire (18 to 24-gauge, 2 conductor) between units; connect as
shown;
¥
Set the end unit to
MASTER CHANNEL A
and ensure that this unit is connected to
either AC power or battery power at all times;
¥
Replace covers and reconnect power;
¥
Set all other units to Slave;
¥
Repeat pattern of
CHANNELS A, C,
and
D
for any additional units
11.4.
AC & DC CONTROL
11.4.1.
AC CONTROL
Connection of an external alarm, locking device or other component may be made as
shown below. The optically-isolated triac output will conduct only during the time that
the Red
ALARM
light is illuminated. It is recommended that the control not exceed
48Vrms and 100mA. The output is electrically isolated from ground.
¥
Open Access Door of detection unit;
¥
Remove three (3) screws that hold
controller cover;
¥
Connect the relay or device to control;
¥
Replace cover and reconnect power.
11.4.2.
DC CONTROL
The three drawings that follow illustrate
alternate methods of connecting an exter-
nal device which has requirements of low
voltage direct current. The output is an open collector configuration capable of switch-
ing 15V at 100mA or less, which includes connections to computing devices and other
equipment requiring low level DC.