Содержание LS4 MINI 43kW

Страница 1: ...LS4 MINI 43kW Box 203 SE 335 25 Gnosj Phone 46 0 370 33 28 00 info garo se garo se Manual 380312 1 0 Assembly instructions End User Instructions EN GARO AB EN...

Страница 2: ...arnings 3 Cautions 4 Notes 4 Content 4 INSTALLATION 5 USER MANUAL 7 Normal use 7 LED indications 7 Dimensional sketch 11 Electrical diagram 12 Technical specifications 15 Service Maintenance 16 Servic...

Страница 3: ...ing to local country installation requirements Do not install or use the LS4 MINI near flammable explosive harsh or combustible materials chemicals or vapors Turn off the electrical power at the circu...

Страница 4: ...g hit by vehicles is minimized Ensure that the charging cable is positioned so it will not be stepped on driven over tripped on or subjected to damage or stress Unroll the charging cable to prevent it...

Страница 5: ...the fuse and cable information in the Installation form located in the installation manual that is included in the box 3 Mount the LS4 MINI on a wall or on a pedestal figure 1 6 Note Wall installatio...

Страница 6: ...L3 N 6Nm PE 2 5 10mm 5Nm 16 50mm 10Nm AL L1 L2 L3 N 2 5 16mm 5Nm 25 50mm 10Nm PE 2 5 10mm 5Nm 16 50mm 10Nm Pedestal Accessory Article number 354386 0 8Nm 0 05 figure 4 figure 5 figure 3 4x ALU CU ada...

Страница 7: ...g station detects that the cable is connected but is yet to detect the EV Blinking green 30 second blink Whenever during operation Charging station have received command from backend to start charging...

Страница 8: ...ent charging cable if available Blinking green 30 second blink Connect the charging cable or verify that cable is connected correctly Check the intake on the EV for obstructions dirt Firm blue No erro...

Страница 9: ...current in backend charger configuration OperatorCurrentLimit Check motor locking wiring and connection for damages Verify that locking mechanism rod and arm are not stuck Verify that the connector is...

Страница 10: ...2DC on the output terminals when red black cables were disconnected then it has detected an earth fault in one of the DC powered components controllers upper PCB router switch etc inside the charging...

Страница 11: ...AUTHORIZED available A Vehicle not connected Firm blue CHARGING occupied C Vehicle connected ready CHARGING suspendedEV B Vehicle connected not ready Blinking blue Reserved Firm red RCD triggered grou...

Страница 12: ...minal Block 1 XD1 Type2 Charging Cable FB1 RCCB 200 201 External Meter Terminal Block 200 201 FC3 Fuse Charge Controller and Powersupply Q1 Main Breaker XPE2 Protection Earth Terminal Block 2 SP Surge...

Страница 13: ...L2 i L3 i N L1 o L2 o L3 o SC 1 2 3 4 5 6 9 8 N N L1 L2 L3 L1 L2 L3 CC1 B Modbus CC1 A Modbus CC1 B Modbus CC1 A Modbus CC1 B Modbus CC1 A Modbus L1 N 12V DC 230 V T1 CC1 Relais 23 12V 0V 0 75 BLACK R...

Страница 14: ...A2 Modbus WA Relais 23 WA Relais 24 Eth 1 10 100 RJ45 HEAT CC1 4G Down side Type 2 Charge cable RED Up Side Antenna AC Terminal QA1 A1 CP 0V 12V P E PE 1A 1B C P PP P1 B 1B 0V DC Terminal P1 A 1A 12V...

Страница 15: ...g type Mode 3 Charging method AC Charging Protection class IP54 Mechanical impact resistance IK10 Temperature range 25C 40C Weight 25kg Standard cable length 7 5m Rated current impuls withstand 10kA R...

Страница 16: ...ntenance form Check point for annual maintenence Status Value Comment remark Visual check outside cabinet LED indication lit Check cables connectors connector pins Check color foil and instructions Ch...

Страница 17: ...UAL Installation Form LS4 MINI Model M nr ELECTRICAL INSTALLATION DATA Group fuse A Supply cable dimension FUNCTION TEST Testbox Date Sign Installer Company Name Owner Customer Name Installation addre...

Страница 18: ...18 EN...

Страница 19: ...GARO AB Box 203 SE 335 25 Gnosj Phone 46 0 370 33 28 00 info garo se garo se EN...

Отзывы: