![GARO LS4 MINI 43kW Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/garo/ls4-mini-43kw/ls4-mini-43kw_assembly-instructions-manual_3600274010.webp)
USER MANUAL
LED light indication Measure 1
Measure 2
NO LIGHT
Reset circuit breaker in upstream switchboard.
Have you tried everything
without success? Contact your
installer or GARO Support.
(please have M-number
available)
Check mainbreaker, reset it if it is deactivated.
Check mainbreaker (1-pole 10A), reset it if it is deactivated.
Verify that 12V power supply unit is receiving 220V AC power
via terminals L & N.
Disconnect red/black cables from the power supply unit terminals
marked "+/-". If the power supply unit delivers 12DC on the
output terminals when red/black cables were disconnected,
then it has detected an earth fault in one of the DC powered
components (controllers, upper PCB, router/switch etc.) inside
the charging station. If LED-light [DC OK] remains turned off,
consider replacing the 12V power supply unit.
Check red/black cable and connection between DC terminal
and upper PCB quick connection (located on far left side of
upper PCB in the charging station).
Verify that the controller has 12 V DC power supplied (4-pole
quick connection on down-side of controller -> terminal 1 & 2
from the left) and that the LED-light [Ready] is blinking green.
If power supply is ok, but no blinking green, then consider
replacing charging controller.
10
EN
Содержание LS4 MINI 43kW
Страница 18: ...18 EN...
Страница 19: ...GARO AB Box 203 SE 335 25 Gnosj Phone 46 0 370 33 28 00 info garo se garo se EN...