![GARO LS4 MINI 43kW Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/garo/ls4-mini-43kw/ls4-mini-43kw_assembly-instructions-manual_3600274009.webp)
USER MANUAL
Firm red
If the orange "alarm" LED indicator on the charge controller is firm
lit, then the charge controller needs to be replaced.
Have you tried everything
without success? Contact your
installer or GARO Support.
(please have M-number
available)
Firm Red light will always
generate an alarm to the
backend operator.
Reset the RCCB inside the charging station.
Verify that the 8-pole quick connection on the charge controller is
properly connected.
Verify correct grounding and phases in building electrical system
When EV is connected: Disconnect charging cable from the
charging station, then the LED indication shall return to GREEN.
Reconnect charging cable to start charging. The charging
will restart automatically after 15 minutes if cable is not
disconnected.
Reset circuit breaker.
Check internal wiring and components for possible reasons for
short circuit.
Verify allowed maximum current in backend charger configuration
(OperatorCurrentLimit).
Check motor locking wiring and connection for damages. Verify
that locking mechanism rod and arm are not stuck.
Verify that the connector is properly inserted into the socket. Light
force may be applied.
Verify that there are no foreign objects inside the socket inlet on
the EV hence blocking the connector.
Check charging cable and connectors for damages. Test with
another cable if available.
Verify that CP and PP connection pins and wires are not loose or
having bad connection.
Verify grounding of charging station.
If replacing cable does not solve the issue, the charge controller
needs to be replaced.
Have you tried everything
without success? Contact your
installer or GARO Support.
(please have M-number
available)
Firm red
(3 seconds)
Verify that the RFID token is approved by backend (contact
backend operator).
Verify that the RFID token is stored in charger internal memory /
whitelist (requires certified technician)
Blinking red
Contact backend operator and ask for remote activation.
LED light indication Measure 1
Measure 2
9
EN
Содержание LS4 MINI 43kW
Страница 18: ...18 EN...
Страница 19: ...GARO AB Box 203 SE 335 25 Gnosj Phone 46 0 370 33 28 00 info garo se garo se EN...